体外循环中脂质微栓过滤的量化及其对脑损伤的影响
一项前瞻性单中心随机对照试验纳入30例体外循环冠状动脉旁路移植患者,比较使用或不使用脂质去除过滤器对脂质微栓及神经认知损伤的影响。结果显示过滤组脂质微栓显著减少,神经元特异性烯醇化酶峰值释放显著降低,且脂质微栓数量与NSE峰值释放相关。
要点
- 脂质去除过滤器可显著减少体外循环后脂质微栓数量。
- 过滤组神经元特异性烯醇化酶峰值释放显著降低。
- 脂质微栓数量与神经元特异性烯醇化酶峰值释放显著相关。
核心结论
- RemoweLL体外循环系统可显著去除心内吸引血中的脂质微栓。
- 脂质微栓与已知神经损伤标志物的释放相关。
研究设计与样本
- 前瞻性单中心随机对照试验,纳入30例体外循环下冠状动脉旁路移植患者,每组15例。
主要发现
- 过滤组心内吸引血过滤后脂质微栓显著减少(p < 0.001),对照组脂质微栓显著升高(p < 0.001)。
- 过滤组神经元特异性烯醇化酶峰值释放显著降低(p = 0.013),术后全程显著衰减(p = 0.002)。
- 体外循环后脂质微栓数量与神经元特异性烯醇化酶峰值释放显著相关(r = 0.42,p = 0.02)。
临床怎么用
- 在体外循环冠状动脉旁路移植中可考虑使用脂质去除过滤器以减少脂质微栓。
- 脂质微栓数量可作为神经损伤风险的参考指标。
局限性
- 样本量较小(30例),单中心设计。
- 未证实脂质微栓与器官功能障碍的因果关系。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Lipid microemboli (LME) are formed in pericardial suction blood which, when returned to the cardiopulmonary bypass (CPB) circuit, can pass through filter materials and are returned to the arterial cannula. LME have been observed to enter all major organs and have been associated with small capillary arteriolar dilatations in the brains of patients who have died after CPB. However, a causal relationship showing correlation between LME and organ dysfunction has not been demonstrated, or whether removal of LME results in improved organ function. METHODS: A prospective, single center, randomized controlled trial examined 30 patients (15 per group) undergoing coronary artery bypass grafting using CPB with or without a lipid-depleting filter. The effects of LME filtration on neurocognitive injury were assessed using neuron-specific enolase (NSE). RESULTS: The study group showed a significant reduction in LME after filtration of the pericardial suction blood (p < 0.001), whereas the control group exhibited a significant rise in LME (p < 0.001). There was a significant reduction in peak NSE release (p = 0.013) and significant attenuation throughout the postoperative period (p = 0.002). Correlation and regression analyses showed a significant relationship between the number of LME post-CPB and peak NSE release (r = 0.42, p = 0.02). CONCLUSIONS: Several methods of LME filtration have been proposed, but none provided a suitable, efficacious method for use within the clinical setting. The RemoweLL CPB system removes significant numbers of LME from the cardiotomy suction. Furthermore, LME correlate to the release of a known marker of neurologic injury.
引用
- Issitt RW, Harvey I, Walsh B, et al. Quantification of Lipid Filtration and the Effects on Cerebral Injury During Cardiopulmonary Bypass. Ann Thorac Surg. 2017. PMID: 28456395. doi:10.1016/j.athoracsur.2017.02.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。