心室辅助装置诱导血清天然IgG抗体并与心脏移植后原发性移植物功能障碍相关
该研究检测了206例心脏移植受者移植前血清中的天然抗体,其中128例曾植入VAD,78例未植入。结果显示VAD患者血清IgG天然抗体水平显著升高,且升高的移植前IgG天然抗体与原发性移植物功能障碍(PGD)的发生相关,提示VAD可能通过非特异性B细胞活化诱导IgG致敏并参与PGD炎症反应。
要点
- VAD植入后心脏移植受者移植前血清IgG天然抗体水平显著升高。
- 移植前升高的IgG天然抗体与心脏移植后PGD发生相关。
- VAD与未VAD患者间血清IgM天然抗体水平无差异。
核心结论
- VAD支持可诱导针对凋亡细胞和氧化表位的IgG天然抗体,支持VAD引起广泛非特异性B细胞活化导致IgG致敏。
- 血清IgG天然抗体水平与PGD发生相关,提示这些抗体可能参与PGD伴随的炎症反应。
研究设计与样本
- 研究纳入206例原位心脏移植受者移植前血清样本,其中VAD患者128例,无VAD患者78例。
- 采用流式细胞术检测血清对凋亡细胞的反应性,采用酶联免疫吸附试验检测对丙二醛氧化表位的反应性,以评估IgM和IgG天然抗体。
主要发现
- VAD患者与无VAD患者血清IgM天然抗体水平无差异。
- VAD患者血清IgG天然抗体水平较无VAD患者显著升高。
- VAD患者植入前血清IgG天然抗体水平较低,提示IgG天然抗体升高可能归因于VAD的存在。
- 移植前升高的IgG天然抗体水平与原发性移植物功能障碍(PGD)的发生相关。
临床怎么用
- 心脏移植术前评估可关注VAD植入史及移植前血清IgG天然抗体水平,以识别PGD高风险受者。
- VAD植入后需考虑非HLA致敏可能,IgG天然抗体或可作为免疫监测的补充指标。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Pre-transplant sensitization is a limiting factor in solid-organ transplantation. In heart transplants, ventricular assist device (VAD) implantation has been associated with sensitization to human leukocyte antigens (HLA). The effect of VAD on non-HLA antibodies is unclear. We have previously shown that polyreactive natural antibodies (Nabs) contribute to pre-sensitization in kidney allograft recipients. Here we assessed generation of Nabs after VAD implantation in pre-transplant sera and examined their contribution to cardiac allograft outcome. METHODS: IgM and IgG Nabs were tested in pre-transplant serum samples collected from 206 orthotopic heart transplant recipients, including 128 patients with VAD (VAD patients) and 78 patients without VAD (no-VAD patients). Nabs were assessed by testing serum reactivity to apoptotic cells by flow cytometry and to the generic oxidized epitope, malondialdehyde, by enzyme-linked immunosorbent assay. RESULTS: No difference was observed in serum levels of IgM Nabs between VAD and no-VAD patients. However, serum IgG Nabs levels were significantly increased in VAD compared with no-VAD patients. This increase was likely due to the presence of the VAD, as revealed by lower serum IgG Nabs levels before implantation. Elevated pre-transplant IgG Nabs level was associated with development of primary graft dysfunction (PGD). CONCLUSIONS: Our study demonstrates that VAD support elicits IgG Nabs reactive to apoptotic cells and oxidized epitopes. These findings further support broad and non-specific B-cell activation by VAD, resulting in IgG sensitization. Moreover, the association of serum IgG Nabs levels with development of PGD suggests a possible role for these antibodies in the inflammatory reaction accompanying this complication.
引用
- See SB, Clerkin KJ, Kennel PJ, et al. Ventricular assist device elicits serum natural IgG that correlates with the development of primary graft dysfunction following heart transplantation. J Heart Lung Transplant. 2017. PMID: 28431981. doi:10.1016/j.healun.2017.03.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。