文献速递主动脉外科

生物型与机械型Bentall手术治疗主动脉根部置换:1112例倾向性评分分析

Biological versus mechanical Bentall procedure for aortic root replacement: a propensity score analysis of a consecutive series of 1112 patients.
PubMed 文献 · Eur J Cardiothorac Surg · 2017-01-01

该研究纳入1978至2011年1112例连续接受完全主动脉根部置换的患者,比较生物型Bentall(BB,356例)与机械型Bentall(MB,756例)的早期死亡、并发症及远期再干预。倾向性评分匹配后两组各138例,院内死亡率相当(MB 7.2% vs BB 5.8%,P=0.6),平均随访40±38个月,全因死亡风险无差异(HR 0.88,95%CI 0.50-2.14,P=0.4),近端主动脉再干预累积免除率1、5、7年MB组为99.1±0.9%,BB组分别为98.4±1.1%、93.0±3.2%、93.0±3.2%(log-rank P=0.07)。结论认为Bentall手术安全可重复,瓣膜移植物类型对早中期不良结局无显著影响。

要点

  • 倾向性匹配后生物型与机械型Bentall的院内死亡率相当(7.2% vs 5.8%,P=0.6)。
  • 随访全因死亡风险与瓣膜类型无关(HR 0.88,95%CI 0.50-2.14,P=0.4)。
  • 近端主动脉再干预免除率两组接近,7年MB组99.1±0.9%,BB组93.0±3.2%(P=0.07)。

核心结论

  • Bentall手术是治疗升主动脉病变安全且可重复的方法。
  • 选择机械型或生物型瓣膜移植物对早期及中期不良结局(包括主动脉再干预需求)无显著影响。

研究设计与样本

  • 回顾性队列研究,纳入1978至2011年1112例连续接受完全主动脉根部置换的患者。
  • 生物型Bentall组356例,机械型Bentall组756例,采用倾向性评分分析处理治疗偏倚,匹配后两组各138例。

主要发现

  • 匹配后院内死亡率两组相当:机械型7.2%,生物型5.8%,P=0.6。
  • 平均随访40±38个月,倾向校正Cox回归显示假体类型与随访全因死亡无关(HR 0.88,95%CI 0.50-2.14,P=0.4)。
  • 近端主动脉再干预免除率1、5、7年机械型组为99.1±0.9%,生物型组分别为98.4±1.1%、93.0±3.2%、93.0±3.2%(log-rank P=0.07)。

临床怎么用

  • 对于升主动脉病变需行主动脉根部置换者,Bentall手术可作为安全可重复的选择。
  • 生物型与机械型瓣膜移植物在早中期死亡和再干预风险上无明显差异,瓣膜类型选择可个体化考虑。

局限性

  • 原文未明确报告局限性内容。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: In this study, a propensity-matching analysis was used to compare biological versus mechanical composite valve graft implantation for early mortality and morbidities and for late complications including the need for aortic reintervention. METHODS: Between 1978 and 2011, 1112 consecutive patients underwent a complete aortic root replacement using either a biological Bentall (BB, n = 356) or a mechanical Bentall (MB, n = 756) valve conduit. Preoperative data were stratified according to the type of valve graft, and treatment bias was addressed by propensity score analysis. RESULTS: Two homogeneous groups of 138 patients were obtained. Hospital mortality between them was comparable (MB = 7.2% and BB = 5.8%, P = 0.6). They also had similar results after a mean follow-up time of 40 ± 38 months. Propensity-adjusted Cox-regression analysis showed no relationship between the type of prosthesis and all-cause mortality at follow-up (hazards ratio: 0.88; 95% confidence interval: 0.50-2.14; P = 0.4). Freedom from proximal aortic reintervention at 1, 5 and 7 years was 99.1 ± 0.9% in the MB group compared with 98.4 ± 1.1%, 93.0 ± 3.2% and 93.0 ± 3.2% in the BB group (long-rank P = 0.07). CONCLUSIONS: The Bentall procedure is a safe and reproducible treatment for ascending aorta pathologies. The choice of either a mechanical or a biological valve graft seems to have no influence on early and late midterm adverse outcomes including need for aortic reinterventions.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Pantaleo A, Murana G, Di Marco L, et al. Biological versus mechanical Bentall procedure for aortic root replacement: a propensity score analysis of a consecutive series of 1112 patients. Eur J Cardiothorac Surg. 2017. PMID: 28407120. doi:10.1093/ejcts/ezx070

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。