外周静脉压评估Fontan循环的中心静脉生理
本研究纳入30例Fontan术后行心导管检查的患者,检验外周静脉压和手臂平衡压能否分别无创估测中心静脉压和平均循环充盈压。结果显示中心静脉压与外周静脉压高度相关(R=0.86,P<.0001),平均循环充盈压与手臂平衡压高度相关(R=0.88,P<.0001)。
要点
- 外周静脉压可无创估测Fontan术后中心静脉压(R=0.86)。
- 手臂平衡压可无创估测平均循环充盈压(R=0.88)。
- 有助于阐明Fontan病理生理并预防Fontan失败。
核心结论
- 中心静脉压和平均循环充盈压可分别通过外周静脉压和手臂平衡压无创估测。
研究设计与样本
- 研究纳入30例Fontan术后行心导管检查的患者(中位8.6年,范围3.4-42年)。
- 测量上肢外周静脉压,并通过Valsalva动作中动脉压和中心静脉压变化计算平均循环充盈压。
- 手臂平衡压通过将血压袖带快速充气至200 mm Hg测量平衡静脉压。
主要发现
- 中心静脉压与外周静脉压高度相关:中心静脉压 = 1.6 + 0.68 × 外周静脉压,R=0.86,P<.0001。
- 逐步多变量回归分析显示仅外周静脉压是中心静脉压的显著决定因素。
- 造影剂注射容量负荷后,回归方程仍能准确估测中心静脉压(R=0.82,P<.0001)。
- 手臂平衡压测量高度可重复,且稳健反映有创测量的平均循环充盈压:平均循环充盈压 = 9.1 + 0.63 × 手臂平衡压,R=0.88,P<.0001。
临床怎么用
- 可利用外周静脉压无创估测Fontan术后中心静脉压,辅助优化管理。
- 可利用手臂平衡压无创估测平均循环充盈压,帮助理解Fontan病理生理。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Elevated central venous pressure is a major cause of morbidity and mortality after the Fontan operation. The difference between mean circulatory filling pressure and central venous pressure, a driving force of venous return, is important in determining dynamic changes in central venous pressure in response to changes in ventricular properties or loading conditions. Thus, noninvasive central venous pressure and mean circulatory filling pressure estimation may contribute to optimal management in patients undergoing the Fontan operation. We tested the hypothesis that central venous pressure and mean circulatory filling pressure in those undergoing the Fontan operation can be simply estimated using peripheral venous pressure and arm equilibrium pressure, respectively. METHODS: This study included 30 patients after the Fontan operation who underwent cardiac catheterization (median 8.6, 3.4-42 years). Peripheral venous pressure was measured at the peripheral vein in the upper extremities. Mean circulatory filling pressure was calculated by the changes of arterial pressure and central venous pressure during the Valsalva maneuver. Arm equilibrium pressure was measured as equilibrated venous pressure by rapidly inflating a blood pressure cuff to 200 mm Hg. RESULTS: Central venous pressure and peripheral venous pressure were highly correlated (central venous pressure = 1.6 + 0.68 × peripheral venous pressure, R = 0.86, P < .0001). Stepwise multivariable regression analysis showed that only peripheral venous pressure was a significant determinant of central venous pressure. Central venous pressure was accurately estimated using regression after volume loading by contrast injection (R = 0.82, P < .0001). In addition, arm equilibrium pressure measurements were highly reproducible and robustly reflected invasively measured mean circulatory filling pressure (mean circulatory filling pressure = 9.1 + 0.63 × arm equilibrium pressure, R = 0.88, P < .0001). CONCLUSIONS: Central venous pressure and mean circulatory filling pressure can be noninvasively estimated by peripheral venous pressure and arm equilibrium pressure, respectively. This should help clarify unidentified Fontan pathophysiology and the mechanisms of Fontan failure progression, thereby helping construct effective tailor-made approaches to prevent Fontan failure.
引用
- Masutani S, Kurishima C, Yana A, et al. Assessment of central venous physiology of Fontan circulation using peripheral venous pressure. J Thorac Cardiovasc Surg. 2016. PMID: 28108065. doi:10.1016/j.jtcvs.2016.11.061
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。