文献速递瓣膜外科

经导管主动脉瓣置换术后瓣叶血栓:瓣叶血液滞留的意义

Valve thrombosis following transcatheter aortic valve replacement: significance of blood stasis on the leaflets.
PubMed 文献 · Eur J Cardiothorac Surg · 2017-01-01

研究通过计算模型比较外科生物瓣与经导管主动脉瓣在瓣中瓣/环内位置下瓣叶血液滞留时间(BRT)。结果显示经导管瓣叶BRT显著更长,前向血流期均值高39%(P<0.0001),舒张期两个阶段分别高150%和40%(P<0.0005),提示几何受限增加BRT,可能促进瓣叶血栓。

要点

  • 经导管主动脉瓣因几何受限,瓣叶血液滞留时间显著长于外科生物瓣。
  • 前向血流期BRT均值高39%,舒张期两个阶段分别高150%和40%。
  • BRT延长可能是经导管瓣膜血栓形成的允许因素。

核心结论

  • 经导管主动脉瓣的几何受限增加瓣叶血液滞留时间,可能作为瓣膜血栓的允许因素。

研究设计与样本

  • 研究构建两个计算模型,分别代表外科生物瓣和经导管主动脉瓣,模拟瓣中瓣/环内位置。
  • 采用单向流固耦合建模获取三维流场,并经实验测试验证。

主要发现

  • 经导管瓣叶BRT在各心动周期阶段均显著长于外科瓣。
  • 前向血流期BRT均值高39%(P<0.0001)。
  • 舒张期从收缩末期至舒张中期BRT均值高150%(P<0.0005)。
  • 舒张期从舒张中期至收缩初期BRT均值高40%(P<0.0005)。

临床怎么用

  • 关注经导管主动脉瓣置换及瓣中瓣术后瓣叶血液滞留增加血栓风险的可能性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Leaflet thrombosis following transcatheter aortic valve replacement (TAVR) and valve-in-valve (ViV) procedures has been increasingly recognized. However, the factors affecting the post-TAVR/ViV thrombosis are not fully understood. This study aimed to investigate the effect of the geometric confinement of transcatheter aortic valve (TAV) on blood residence time (BRT) on the TAV leaflets and in turn on the post-TAVR valve thrombosis. METHODS: Two computational models, representing a surgical bioprosthesis and a TAV, were developed to study the effect of the geometric confinement on BRT on the leaflets in ViV setting/TAVR Intra-annular positioning. 3D flow fields were obtained via a one-way fluid-solid interaction modelling approach validated by experimental testing. BRT was compared between the two models by quantification and statistical analysis of the residence time of randomly distributed particles in close proximity of the leaflets. RESULTS: Significantly longer BRT on the leaflets was observed in the TAV compared to the surgical valve during different stages of the cardiac cycle. During forward flow, the mean value of BRT was found to be 39% higher in the TAV compared to the surgical bioprosthesis ( P < 0.0001). During diastole, specifically from end-systole to mid-diastole and from mid-diastole to the beginning of systole, the amount by which the mean BRT was higher for TAV compared to the surgical valve was 150% and 40%, respectively ( P < 0.0005). CONCLUSIONS: The geometric confinement of TAV by the failed bioprosthesis or the calcified native valve increases the BRT on the TAV leaflets. This may act as a permissive factor in valve thrombosis.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Vahidkhah K, Barakat M, Abbasi M, et al. Valve thrombosis following transcatheter aortic valve replacement: significance of blood stasis on the leaflets. Eur J Cardiothorac Surg. 2017. PMID: 28100471. doi:10.1093/ejcts/ezw407

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。