文献速递冠心病外科

CORONARY试验:非体外循环冠状动脉旁路移植术中转体外循环的经验

Conversion after off-pump coronary artery bypass grafting: the CORONARY trial experience.
PubMed 文献 · Eur J Cardiothorac Surg · 2017-01-01

CORONARY试验纳入4718例随机接受非体外或体外冠状动脉旁路移植术的患者,非体外循环术中转为体外循环的发生率为7.9%(186/2356)。紧急转流(因低血压或心肌缺血)占3.2%(75例),多数择期转流因冠状动脉细小或壁内走行(83例)。紧急转流患者1年复合终点(死亡、卒中、心肌梗死或需透析的新发肾衰竭)发生率高于未转流者,而择期转流与未转流者无差异。

要点

  • 非体外循环CABG术中转为体外循环的发生率为7.9%。
  • 紧急转流占3.2%,与更差的1年复合终点相关。
  • 择期转流 outcomes 与未转流者无显著差异(P=0.35)。

核心结论

  • 紧急OFF-to-ON转流相比择期转流或未转流与更差的结局相关。

研究设计与样本

  • CORONARY试验是一项随机对照试验,共4718例患者随机接受非体外或体外循环CABG,其中非体外组2356例中186例(7.9%)发生术中转流。

主要发现

  • 紧急转流(因低血压或心肌缺血)占3.2%(n=75),多数择期转流因冠状动脉细小或壁内走行(n=83)。
  • 转流患者手术时间、输血和ICU停留增加,1年复合终点发生率高于未转流的非体外患者(所有P<0.01),紧急转流者尤为明显。
  • 择期转流患者的结局与未转流的非体外患者无差异(P=0.35)。
  • 紧急转流的独立预测因素包括心率较高或慢性心房颤动、急诊手术、计划移植血管数较多以及外科医生非体外CABG经验。

临床怎么用

  • 存在紧急转流危险因素时,早期择期转流是明智策略。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Emergent and late conversions form OFF-to-ON pump coronary artery bypass grafting (CABG) have been associated with worse outcomes, however, it remains unclear as to which risk factors are associated with conversion and how to prevent them. METHODS: Among 4718 patients who randomly underwent off- or on-pump CABG, the incidence of off-pump to on-pump cross-over, or 'OFF-to-ON conversion', was 7.9% (186/2356). The primary outcome was a composite of death, stroke, myocardial infarction, or new renal failure requiring dialysis. We assessed the risk factors and outcomes of converted patients. RESULTS: Emergent OFF-to-ON conversions, defined as conversions for hypotension or ischaemia, were required for 3.2% of patients ( n = 75), while most elective conversions were due to small or intramuscular coronaries ( n = 83). OFF-to-ON converted patients required increased surgery time, blood transfusions, intensive care unit stay, and presented a higher incidence at 1 year of the composite outcome compared with non-converted off-pump patients (all P < 0.01), especially if the conversion was emergent. Conversely, elective conversions outcomes were no different compared with non-converted off-pump patients ( P = 0.35). Independent predictors of emergent conversions included higher heart rate or chronic atrial fibrillation, urgent surgery, more grafts planned and surgeon experience with off-pump CABG. CONCLUSIONS: Emergent OFF-to-ON conversion is associated with worse outcomes compared with elective conversion or no conversion. In the presence of risk factors for emergent conversion, an early and elective conversion approach is a judicious strategy.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Stevens LM, Noiseux N, Avezum A, et al. Conversion after off-pump coronary artery bypass grafting: the CORONARY trial experience. Eur J Cardiothorac Surg. 2017. PMID: 28082464. doi:10.1093/ejcts/ezw361

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。