过度减少体外循环预充量的非预期后果
该研究基于47,273例孤立冠状动脉旁路移植术的多中心注册数据,评估限制体外循环预充量对术中红细胞输注的影响。结果显示预充量与输注风险呈非线性关系,预充量低于患者估计血容量的15%并不减少输血,反而可能增加暴露。
要点
- 预充量与术中红细胞输注风险呈显著非线性关系。
- 预充量低于估计血容量15%不减少输血,可能增加暴露。
- 需进一步研究预充量对输血及患者结局的影响。
核心结论
- 将预充量降至患者估计血容量15%以下不能保护患者免于术中红细胞输注,反而可能增加输血暴露。
研究设计与样本
- 多中心注册回顾性研究,纳入189家机构2012年4月至2015年5月间47,273例孤立冠状动脉旁路移植术。
- 采用多变量逻辑回归模型控制13项混杂因素,并用限制性立方样条评估非线性关系。
主要发现
- 预充量与输注≥1单位红细胞风险呈显著非线性关系(χ2=116.3,df=4,p<0.001)。
- 预充量与输注≥4单位红细胞风险呈显著非线性关系(χ2=25.9,df=4,p<0.001)。
- 输注≥1单位红细胞的最低概率估计出现在预充量与估计血容量比值为0.152时(p<0.001)。
临床怎么用
- 临床不应将预充量降至患者估计血容量15%以下以图减少术中输血。
- 预充量管理需权衡患者发病率与血液利用的经济影响。
局限性
- 原文未明确报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The Society of Thoracic Surgeon blood conservation guidelines recommend minimizing cardiopulmonary bypass circuit prime volume (PV) as an integral, evidence-based (Class I, Level A) blood conservation strategy. We used a large, multiinstitutional registry to evaluate the effectiveness of restricting cardiopulmonary bypass PV on intraoperative red blood cell (RBC) transfusion. METHODS: We reviewed 47,273 isolated coronary artery bypass graft procedures performed among 189 institutions between April 2012 and May 2015. The primary outcome was intraoperative transfusion of at least 1 unit RBC; the secondary outcome was intraoperative transfusion of 4 or more units RBC. We estimated the adjusted odds of each transfusion type using separate multivariable logistic regression models that controlled for 13 confounding factors. The effect of PV on odds of transfusion was modeled using restricted cubic splines to assess possible nonlinearity. RESULTS: We found a statistically significant nonlinear pattern in the relation between PV and odds of transfusion of both 1 or more units RBC (χ2 = 116.3, df = 4, p < 0.001) and 4 or more units RBC (χ2 = 25.9, df = 4, p < 0.001). The lowest probability of transfusion of 1 or more units RBC was estimated at a ratio of PV to estimated blood volume of 0.152 (p < 0.001). CONCLUSIONS: Efforts to minimize PV below 15% of a patient's estimated blood volume do not protect patients from intraoperative RBC transfusion, and may increase exposure. Prime volume can affect both patient morbidity and the economic impact associated with blood utilization. Further studies on the effect of PV on blood transfusion are warranted.
引用
- Sun BC, Dickinson TA, Tesdahl EA, et al. The Unintended Consequences of Over-Reducing Cardiopulmonary Bypass Circuit Prime Volume. Ann Thorac Surg. 2016. PMID: 28012641. doi:10.1016/j.athoracsur.2016.09.099
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。