文献速递心外重症与机械循环支持

低流量右心室机械支持对急慢性压力负荷过重右心室的收缩与舒张卸载差异

Systolic and diastolic unloading by mechanical support of the acute vs the chronic pressure overloaded right ventricle.
PubMed 文献 · J Heart Lung Transplant · 2016-10-17

该研究在18只肺动脉环缩绵羊中比较急性(n=9)与慢性(n=9)右心室压力负荷过重时低流量右心室机械支持的即刻血流动力学效应。「Synergy」微泵从右心房向肺动脉转流,记录泵启动前及启动后15分钟的血流动力学与压力-容积环。结果显示两组动脉血压均改善,但仅急性组心输出量增加;舒张卸载两组均成功,收缩卸载仅慢性组成功,慢性组右心室对总右心输出量贡献更低(10%±13 vs 54%±8,p<1.10-5)。

要点

  • 低流量右心室机械支持改善急慢性右心室压力负荷过重时的动脉血压。
  • 舒张卸载在急慢性两组均成功,收缩卸载仅在慢性组成功。
  • 慢性组右心室对总右心输出量贡献显著低于急性组,提示卸载更彻底。

核心结论

  • 低流量右心室机械支持在急性与慢性右心室压力负荷过重中均改善动脉血压,但慢性组卸载更彻底。
  • 舒张卸载两组均成功,收缩卸载仅在慢性组成功。

研究设计与样本

  • 18只绵羊行肺动脉环缩,急性组(n=9)即刻植入Synergy Pocket Micro-Pump,慢性组(n=9)于环缩8周后植入。
  • 泵从右心房向右肺动脉转流,记录泵启动前及启动后15分钟的血流动力学与压力-容积环。

主要发现

  • 低流量右心室机械支持显著改善两组动脉血压,但心输出量仅在急性组增加。
  • 内在右心室收缩力未受影响。
  • 右心室对总右心输出量贡献:急性组54%±8,慢性组10%±13(p<1.10-5),提示慢性组卸载更彻底。
  • 中心静脉压、舒张末压与容积及心室顺应性下降反映的舒张卸载两组均成功。
  • 压力-容积面积与右心室峰值压力下降反映的收缩卸载仅在慢性组成功。

临床怎么用

  • 低流量右心室机械支持可用于急性与慢性右心室压力负荷过重,但慢性者收缩卸载更明显。
  • 慢性右心室压力负荷过重患者使用低流量支持需进一步研究长期效应。

局限性

  • 研究为动物实验(绵羊),样本量小(每组n=9),仅观察泵启动后15分钟即刻效应。
  • 长期疗效与安全性尚未评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Right ventricular (RV) mechanical support is well described in cases of sudden increase in RV afterload. In cases of chronic RV pressure overload (e.g., pulmonary arterial hypertension), it has rarely been described. METHODS: The pulmonary artery was banded in 18 sheep. In the acute group (n = 9), we immediately implanted a Synergy Pocket Micro-Pump. Blood was withdrawn from the right atrium to the pulmonary artery. In the chronic group (n = 9), this pump was implanted 8 weeks after banding. Hemodynamics and pressure-volume loops were recorded before and 15 minutes after pump activation. RESULTS: Low-flow RV mechanical support significantly improved arterial blood pressure in both groups, but cardiac output only in the acute group. Intrinsic RV contractility was not affected. The RV contribution to the total right-sided cardiac output was 54% ± 8 in the acute group vs 10% ± 13 in the chronic group (p < 1.10-5), indicating a more profound unloading in the latter. Diastolic unloading (reflected by decreases in central venous pressure, end-diastolic pressure and volume, and ventricular capacitance) was successful in both groups. Decreases in pressure-volume area and RV peak pressure reflected successful systolic unloading only in the chronic group. CONCLUSIONS: Low-flow RV mechanical support improved arterial blood pressure in both conditions but caused a more profound unloading in the chronic group. Diastolic unloading was successful in both groups, but systolic unloading was successful only in the chronic group. The potential use of low-flow mechanical support for a chronic pressure overloaded right ventricle warrants further research to assess its long-term effects.

来源:J Heart Lung Transplant,查看原文。版权归原作者所有。

引用

  1. Verbelen T, Burkhoff D, Kasama K, et al. Systolic and diastolic unloading by mechanical support of the acute vs the chronic pressure overloaded right ventricle. J Heart Lung Transplant. 2016. PMID: 27865733. doi:10.1016/j.healun.2016.10.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。