电外科分隔术适用于全谱系主动脉夹层
该回顾性研究纳入21例连续接受电外科分隔术的降主动脉夹层患者,技术成功率95%,灌注不良全部缓解,灌注腔指数从0.16升至0.98(P<0.001),无卒中、脊髓缺血或逆行A型夹层,但队列小、随访短,仅证明可行性。
要点
- 电外科分隔术可用于全谱系降主动脉夹层,技术成功率95%。
- 灌注不良患者术后全部缓解,灌注腔指数显著改善。
- 无卒中、脊髓缺血或逆行A型夹层,但随访仅5.1个月。
核心结论
- 电外科分隔术在全谱系主动脉夹层中可行,对部分灌注不良患者可单独治疗。
- 因队列小且异质、随访短,结果仅证明可行性而非持久性。
研究设计与样本
- 回顾性意向性治疗分析,纳入2022年6月至2026年5月连续21例计划行分隔术的患者。
主要发现
- 21例中20例完成分隔术,意向性治疗技术成功率95%。
- 灌注不良7例全部缓解,灌注腔指数中位数从0.16升至0.98(18例,P<0.001)。
- 发生1例迟发性主动脉破裂死亡,无术中死亡,3例非计划再干预,中位随访5.1个月。
关键数值与推荐
- 适应证包括着陆区准备(57%)、灌注不良(33%)、开放修复准备和真腔塌陷。
- 在透视下以40-60 W电化贯通导丝分隔内膜片,不常规使用血管内超声或图像融合。
临床怎么用
- 对降主动脉夹层合并灌注不良等选定患者,可考虑电外科分隔术作为单独治疗。
- 使用标准电外科设备,在透视下操作,不常规依赖血管内超声或图像融合。
局限性
- 回顾性、小样本、异质性队列。
- 随访时间短,中位仅5.1个月。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Transcatheter electrosurgical septotomy divides the dissection membrane to reconstitute a single aortic lumen. Reported experience is largely confined to chronic post-dissection aneurysms. We assessed the technique across the full spectrum of descending aortic dissection, including stand-alone treatment of malperfusion. METHODS: Retrospective intention-to-treat analysis of 21 consecutive patients scheduled for septotomy between June 2022 and May 2026. The membrane was crossed by needle re-entry and divided with an electrified through-and-through guidewire at 40-60 W under fluoroscopy, without routine intravascular ultrasound or image fusion. A perfused-lumen index (perfused lumen divided by total aortic diameter) was measured before and after the procedure. RESULTS: Septotomy was performed in 20 of 21 patients (technical success 95% on an intention-to-treat basis). Indications were landing-zone preparation (57%), malperfusion (33%), preparation for open repair and true-lumen collapse. Malperfusion resolved in all 7 patients treated for that indication, and the perfused-lumen index rose from a median of 0.16 to 0.98 (18 patients, P < 0.001). There was no stroke, spinal cord ischaemia or retrograde type A dissection. Thirty-day, in-hospital and overall mortality were 10%, 14% and 19%, with one fatal delayed aortic rupture and no intraprocedural death. Three unplanned reinterventions occurred; median follow-up was 5.1 months. CONCLUSIONS: Electrosurgical septotomy was feasible across the full spectrum of aortic dissection and, in selected patients, as stand-alone treatment for malperfusion, using standard electrosurgical equipment. Given the small heterogeneous cohort and short follow-up, these findings demonstrate feasibility rather than durability.
引用
- Weiss G, Trnka H, Tauber S, et al. Electrosurgical septotomy across the full spectrum of aortic dissection. Eur J Cardiothorac Surg. 2026. PMID: 42902781. doi:10.1093/ejcts/ezag246
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。