主动脉形态对降主动脉瘤TEVAR远期结局的影响:日本全国注册研究

Impact of aortic morphology on long-term outcomes after thoracic endovascular aortic repair for descending thoracic aortic aneurysm: A nationwide registry study.
PubMed 文献 · J Thorac Cardiovasc Surg · 2026-07-31

基于日本JACSM全国注册数据,纳入10,293例因退行性降主动脉瘤行首次TEVAR的患者,分析主动脉形态与远期动脉瘤相关死亡和再干预的关系。中位随访显示10年免于动脉瘤相关死亡和再干预分别为75.5%和88.4%,瘤径、近远端锚定区直径及出院前内漏与不良结局相关。

要点

  • 瘤径增大与再干预风险升高相关,75mm时HR为2.21(95%CI 1.73-2.83,以50mm为参照)。
  • 近端锚定区直径35mm较30mm再干预HR增至1.59(95%CI 1.30-1.96)。
  • 远端锚定区直径和出院前内漏亦与动脉瘤相关死亡或再干预相关。

核心结论

  • 术前瘤径及近远端锚定区直径与退行性降主动脉瘤TEVAR术后远期动脉瘤相关死亡和再干预相关。

研究设计与样本

  • 日本JACSM全国前瞻性注册研究,2008至2015年共23,303例TEVAR,排除353例早期死亡后纳入10,293例首次TEVAR的退行性降主动脉瘤患者。

主要发现

  • 10年免于动脉瘤相关死亡为75.5%,免于再干预为88.4%。
  • 多因素分析显示瘤径、远端锚定区直径和出院前内漏与动脉瘤相关死亡相关。
  • 瘤径、近端和远端锚定区直径、zone 2锚定及出院前内漏为再干预的显著预测因素。
  • 限制性立方样条显示再干预HR随瘤径增大而升高,75mm时HR为2.21(95%CI 1.73-2.83,以50mm为参照)。
  • 近端锚定区直径35mm较30mm再干预HR为1.59(95%CI 1.30-1.96),远端锚定区直径35mm较30mm再干预HR为1.22(95%CI 0.96-1.53)。

临床怎么用

  • TEVAR术前应评估瘤径及近远端锚定区直径,瘤径较大或锚定区直径较大的患者需加强远期再干预监测。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To identify anatomic factors associated with long-term outcomes after thoracic endovascular aortic repair (TEVAR) for degenerative descending thoracic aortic aneurysm (DTAA) using a nationwide registry in Japan. METHODS: A total of 23,303 TEVAR cases from 2008 to 2015 were collected prospectively by the Japanese Committee for Stentgraft Management (JACSM). Of these, 10,293 patients who underwent initial TEVAR for degenerative DTAA were enrolled, after excluding 353 early deaths. Cox regression analysis was performed to identify factors associated with aneurysm-related death and reintervention. Adjusted restricted cubic spline (RCS) analysis was applied to examine potential nonlinear relationships between significant anatomic factors and outcomes. RESULTS: The mean patient age was 74 ± 8 years, and 7748 patients (75%) were male. Ten-year freedom from aneurysm-related death and reintervention was 75.5% and 88.4%, respectively. On multivariate analysis, aneurysm diameter, distal neck diameter, and predischarge endoleak were associated with aneurysm-related death. Aneurysm diameter, proximal and distal neck diameters, zone 2 landing, and predischarge endoleak were significant predictors of reintervention. RCS analysis for reintervention showed that increasing aneurysm diameter was associated with a higher hazard ratio (HR), reaching 2.21 (95% confidence interval [CI], 1.73-2.83) at 75 mm using 50 mm as a reference. For proximal neck diameter, the HR increased to 1.59 (95% CI, 1.30-1.96) to 35 mm compared with 30 mm. For distal neck diameter, the HR reached 1.22 (95% CI, 0.96-1.53) at 35 mm compared with 30 mm. CONCLUSIONS: The JACSM registry demonstrated that preoperative aneurysm diameter and neck diameters were associated with long-term outcomes after TEVAR for DTAA.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Shijo T, Shimamura K, Hoshina K, et al. Impact of aortic morphology on long-term outcomes after thoracic endovascular aortic repair for descending thoracic aortic aneurysm: A nationwide registry study. J Thorac Cardiovasc Surg. 2026. PMID: 42537783. doi:10.1016/j.jtcvs.2026.07.015