文献速递瓣膜外科主动脉外科

形态正常三叶式主动脉瓣有效高度的决定因素:基于CT的解剖学研究

Determinants of effective height in morphologically normal tricuspid aortic valves: A computed tomography-based anatomical study.
PubMed 文献 · Interdiscip Cardiovasc Thorac Surg · 2026-08-20

该回顾性研究纳入105例形态正常的主动脉瓣、主动脉根或升主动脉患者,利用心电门控心脏CT于舒张期测量主动脉瓣复合体各形态参数。结果发现有效高度与几何高度、Valsalva窦直径、窦管交界直径、连合高度及Valsalva高度显著相关,多因素分析显示几何高度、主动脉瓣环直径和窦管交界直径是有效高度的独立相关因素。

要点

  • 有效高度与几何高度、Valsalva窦直径、窦管交界直径、连合高度及Valsalva高度显著相关。
  • 多因素分析示几何高度、主动脉瓣环直径和窦管交界直径与有效高度独立相关。
  • 结果可为主动脉瓣修复个体化策略研究提供解剖参考数据。

核心结论

  • 有效高度与几何高度强相关,校正后几何高度、主动脉瓣环直径和窦管交界直径仍与有效高度独立相关。
  • 结果为形态正常三叶式主动脉瓣有效高度的解剖决定因素提供体内定量证据。

研究设计与样本

  • 纳入对象为形态正常的主动脉瓣、主动脉根或升主动脉,使用Ziostation2软件于舒张期测量主动脉瓣复合体参数。
  • 采用Pearson相关分析有效高度与其他参数的关系,并行多因素回归分析评估独立相关变量。

主要发现

  • 有效高度与几何高度、Valsalva窦直径、窦管交界直径、连合高度及Valsalva高度均显著相关(均p < 0.001)。
  • 有效高度与主动脉瓣环直径无显著相关(p = 0.227)。
  • 多因素分析示几何高度、主动脉瓣环直径和窦管交界直径与有效高度独立相关(均p < 0.001;整体模型拟合R2=0.739)。

关键数值与推荐

  • 有效高度与几何高度、Valsalva窦直径、窦管交界直径、连合高度、Valsalva高度的相关性均p < 0.001。
  • 有效高度与主动脉瓣环直径相关性p = 0.227。
  • 多因素模型中几何高度、主动脉瓣环直径、窦管交界直径均p < 0.001,整体模型R2=0.739。

临床怎么用

  • 测量几何高度、主动脉瓣环直径和窦管交界直径有助于预估形态正常三叶式主动脉瓣的有效高度。
  • 可作为主动脉瓣修复个体化方案解剖参考,但需结合患者具体情况判断。

局限性

  • 为单中心回顾性研究,样本量105例。
  • 研究对象为形态正常的三叶式主动脉瓣,结果外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To analyse the relationship between effective height and other morphological parameters of the aortic valve complex when the aortic valve is closed. METHODS: We retrospectively analysed 105 patients (mean age 70.7±10.1 years) with morphologically normal aortic valves, roots, or ascending aortas who had undergone electrocardiography-gated cardiac computed tomography as a screening test of the coronary artery, from August 2014 to December 2018. Parameters of the aortic valve complex configuration (effective height, geometric height, aortic annular diameter, sinus of Valsalva diameter, sinotubular junction diameter, commissure height, and Valsalva height) in diastole were measured using Ziostation2 software. Pearson's correlation was used to evaluate the associations between the effective height and other parameters. Multiple regression analysis was performed to evaluate the variables independently associated with effective height. RESULTS: Significant associations were observed between the effective height and geometric height, sinus of Valsalva diameter, sinotubular junction diameter, commissure height, and Valsalva height (all p < 0.001) but not between effective height and aortic annular diameter (p = 0.227). Multivariable analysis showed that geometric height, aortic annular diameter, and sinotubular junction diameter were independently associated with effective height (all p < 0.001; overall model fit: R2=0.739). CONCLUSIONS: Our findings demonstrate that effective height is strongly associated with geometric height, which remained independently associated after adjustment, along with aortic annular and sinotubular junction diameters. These results provide quantitative in vivo evidence regarding the anatomical determinants of effective height in morphologically normal tricuspid aortic valves and may serve as anatomical reference data for future research on individualised approaches to aortic valve repair.

来源:Interdiscip Cardiovasc Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Ishida K, Igarashi T, Yokoyama H, et al. Determinants of effective height in morphologically normal tricuspid aortic valves: A computed tomography-based anatomical study. Interdiscip Cardiovasc Thorac Surg. 2026. PMID: 42623109. doi:10.1093/icvts/ivag233

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。