文献速递先天性心脏病外科

搏动性与非搏动性体外循环对神经结局影响的随机临床试验

Randomized Clinical Trial Comparing Effects of Pulsatile vs Nonpulsatile Cardiopulmonary Bypass on Neurologic Outcomes.
PubMed 文献 · Ann Thorac Surg · 2026-05-11

该研究为随机临床试验的二次分析,纳入144例18岁以下先天性心脏病手术患儿,随机接受搏动性或非搏动性灌注。两种灌注方式在各时间点的S100B水平相似,神经损伤发生率分别为非搏动性15例和搏动性21例,S100B与神经损伤无显著关联。结论认为灌注方式选择不影响S100B水平,S100B预测神经损伤的敏感性不足。

要点

  • 搏动性与非搏动性灌注在各时间点S100B水平相似。
  • 神经损伤共36例,非搏动性15例,搏动性21例。
  • S100B在体外循环期间升高,撤机前和撤机后1小时最高。

核心结论

  • 灌注方式的选择似乎不影响S100B水平。
  • S100B测量可能不足以可靠预测先天性心脏病体外循环手术患者的神经损伤。

研究设计与样本

  • 随机临床试验的二次分析,纳入144例18岁以下先天性心脏病手术患者,随机分为非搏动性灌注70例和搏动性灌注74例。
  • 在5个时间点测量S100B水平:切皮前基线、转机后3至5分钟、撤机前、撤机后1小时和撤机后24小时。

主要发现

  • 搏动性灌注产生与非搏动性灌注相似的体外循环特征,并在大脑中动脉和动脉管路产生更大的搏动指数。
  • 所有测量时间点的S100B水平在两种灌注方式间相似。
  • 36例患者发生神经损伤(非搏动性15例,搏动性21例),有无神经损伤患者的S100B水平在所有时间点均相似。
  • 所有组中S100B水平在体外循环期间升高,撤机前和撤机后1小时最高。
  • 24小时S100B水平与临床结局呈弱关联(0.25 < rS < 0.5)。

临床怎么用

  • 选择搏动性或非搏动性灌注时,无需基于S100B水平或神经损伤预测来决定。
  • S100B不宜作为先天性心脏病体外循环术后神经损伤的可靠预测指标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The objective of this secondary analysis was to examine the impact of 2 perfusion modalities on S100 calcium-binding protein B (S100B) levels and neural injury outcomes in patients undergoing congenital heart surgery with cardiopulmonary bypass (CPB). METHODS: Pediatric patients (aged <18 years) were randomly assigned to nonpulsatile or pulsatile perfusion. S100B levels were measured in patients at 5 time points (baseline before incision, 3 to 5 minutes on pump, right before weaning from CPB, 1 hour after CPB, and 24 hours after CPB). All patients were assessed for short-term clinical outcomes and with chart review for postsurgical neural injury: stroke, seizure, white matter injury, developmental delays, behavioral issues, memory loss, unexplained loss of consciousness, hearing impairment, and attention-deficit/hyperactivity disorder. RESULTS: A total of 144 consecutive patients were enrolled (70 nonpulsatile, 74 pulsatile). Pulsatile perfusion produced CPB characteristics similar to those of nonpulsatile perfusion and created a greater pulsatility index in the middle cerebral artery and arterial line. S100B levels at all measured time points were similar between both perfusion modalities. A total of 36 patients had neural injuries (15 nonpulsatile, 21 pulsatile). Additionally, S100B levels at all measured time points were similar in patients with and without neural injury. In all groups, S100B levels rose during CPB and were greatest before weaning from CPB and 1 hour after CPB. The 24-hour S100B levels had a weak association with clinical outcomes (0.25 <rS <0.5). CONCLUSIONS: The choice of perfusion modality did not appear to affect S100B levels. Additionally, the measurements of S100B may not be sufficiently sensitive to predict neural injury reliably in patients with congenital heart defects who are undergoing CPB.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Rajesh S, Dayi K, Lussier MJ, et al. Randomized Clinical Trial Comparing Effects of Pulsatile vs Nonpulsatile Cardiopulmonary Bypass on Neurologic Outcomes. Ann Thorac Surg. 2026. PMID: 42119757. doi:10.1016/j.athoracsur.2026.04.046

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。