三尖瓣柔性带与硬质环成形术随机试验:JPH2019 结果
单中心随机试验纳入中度及以上三尖瓣反流成人患者400例按1:1分组,最终321例分析(柔性带156例、硬质环165例)。主要终点为随访期复发性三尖瓣反流。出院时柔性带组复发率显著高于硬质环组(10.1% vs 3.8%,P=.03),但随访期差异不再显著(6.1%/患者年 vs 4.7%/患者年,P=.21)。两组不良事件率相似。
要点
- 出院时柔性带组复发性三尖瓣反流显著高于硬质环组(10.1% vs 3.8%)。
- 随访期复发性三尖瓣反流两组差异无统计学意义(6.1%/患者年 vs 4.7%/患者年)。
- 女性、术前重度或大量三尖瓣反流及术前起搏器植入为复发独立危险因素。
核心结论
- 两种成形装置在中位3年随访中均提供可接受的三尖瓣反流矫正效果,不良事件率相似。
研究设计与样本
- 单中心随机试验,400例中度及以上三尖瓣反流成人患者按1:1随机分组,最终321例纳入分析(柔性带156例,硬质环165例)。
主要发现
- 出院时柔性带组复发性三尖瓣反流显著高于硬质环组(10.1% vs 3.8%,P=.03)。
- 随访期复发性三尖瓣反流两组差异无统计学意义(6.1%/患者年 vs 4.7%/患者年,P=.21)。
- 多变量分析显示女性(sHR 2.16,95%CI 1.1-4.22,P=.025)、术前重度三尖瓣反流(sHR 2.09,95%CI 1.06-4.11,P=.033)和大量三尖瓣反流(sHR 4.63,95%CI 1.29-16.61,P=.019)及术前永久起搏器植入(sHR 3.69,95%CI 1.35-10.09,P=.011)为复发性三尖瓣反流的独立危险因素。
- 基于上述因素亚组分析显示主要终点两组间无显著差异,随访期次要终点两组相当。
临床怎么用
- 对于中度及以上三尖瓣反流患者,柔性带与硬质环均可用于成形矫正,需结合患者复发危险因素个体化选择装置。
局限性
- 单中心设计,最终分析仅纳入321/400例随机患者,可能影响结果外推。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To compare the efficacy and clinical outcomes of flexible band versus rigid ring annuloplasty for the correction of moderate tricuspid regurgitation (TR) or greater. METHODS: In this single-center randomized trial, adult patients with moderate or greater TR were assigned to receive either a flexible band or a rigid ring. The primary outcome was recurrent TR during follow-up. Secondary outcomes included death, permanent pacemaker implantation, and other adverse events. RESULTS: In total, 400 patients were randomized with a 1:1 ratio, and 321 were included in the final analysis (flexible band, n = 156; rigid ring, n = 165). Baseline characteristics were balanced between arms. At discharge, recurrent TR was significantly greater in the flexible band arm than the rigid ring arm (10.1% vs 3.8%, P = .03). However, the significance was no longer significant during follow-up (6.1%/patient-years vs 4.7%/ patient-years, P = .21). Multivariable analysis identified female sex (subdistribution hazard ratio [sHR], 2.16, 95% CI, 1.1-4.22, P = .025), preoperative severe TR (sHR, 2.09; 95% CI, 1.06-4.11, P = .033) and massive TR (sHR, 4.63; 95% CI, 1.29-16.61, P = .019), and preoperative permanent pacemaker implantation (sHR, 3.69; 95% CI, 1.35-10.09, P = .011) as independent risk factors for recurrent TR. Subgroup analyses based on these factors showed no significant between-arm difference in the primary outcome. secondary outcomes were also comparable between the arms during follow-up. CONCLUSIONS: Both annuloplasty devices provided acceptable TR correction with similar adverse event rates over a median 3-year follow-up.
引用
- Xu X, Gu J, Liu H, et al. Randomized trial of tricuspid flexible band versus rigid ring in patients with moderate tricuspid regurgitation or greater: results of the JPH2019 trial. J Thorac Cardiovasc Surg. 2026. PMID: 42092510. doi:10.1016/j.jtcvs.2026.04.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。