文献速递冠心病外科

通畅的胸廓内动脉至左前降支桥血管在再次冠状动脉旁路移植术中仍是风险因素吗?

Is a patent internal thoracic artery-to-left anterior descending artery still a risk factor in patients undergoing isolated redo coronary artery bypass grafting?
PubMed 文献 · J Thorac Cardiovasc Surg · 2026-05-04

该研究比较了通畅的胸廓内动脉(ITA)至左前降支(LAD)桥血管(组1)与狭窄或无ITA-LAD桥血管(组2)患者再次冠状动脉旁路移植术(CABG)的结局。1990年至2023年间共5616例孤立性再次CABG患者,倾向性评分匹配后1762对。结果显示通畅ITA-LAD桥血管损伤发生率为1.8%,但两组主要并发症和手术死亡率相似。

要点

  • 通畅ITA-LAD桥血管在再次CABG中损伤风险为1.8%,多数为左ITA。
  • 桥血管粘连于胸骨或胸壁是损伤的重要危险因素。
  • 经仔细规划,再次CABG在特定患者中可安全实施。

核心结论

  • 通畅ITA-LAD桥血管的再次CABG技术难度大且存在ITA损伤风险,但经仔细规划可安全实施。

研究设计与样本

  • 回顾性队列研究,纳入1990年1月至2023年1月在Cleveland Clinic接受孤立性再次CABG的5616例患者,组1(通畅ITA-LAD)1792例,组2(狭窄或无ITA-LAD)3824例,倾向性评分匹配后1762对。

主要发现

  • 通畅ITA损伤发生率为1.8%(33/1792),其中32/33(97%)为左ITA。
  • 8例(25%)桥血管粘连于胸骨,6例(19%)粘连于胸壁,1例(3%)跨越中线。

临床怎么用

  • 再次CABG前应评估通畅ITA-LAD桥血管的走行及粘连情况,制定个体化手术策略以降低损伤风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To compare outcomes of redo coronary artery bypass grafting (CABG) in the setting of a patent internal thoracic artery (ITA) to left anterior descending artery (LAD) (group 1) versus those with a stenotic ITA-LAD or without ITA-LAD (group 2). METHODS: From January 1990 to January 2023, 5616 patients underwent isolated redo CABG at the Cleveland Clinic-1792 in group 1 and 3824 in group 2-following institutional reoperative protocols. End points included ITA injury, major postoperative morbidities, and operative mortality. Mean age was 64 ± 9.0 years for group 1 and 66 ± 8.7 for group 2. Propensity-score matching yielded 1762 matched patient pairs. RESULTS: Patent ITAs were injured in 1.8% (33/1792), with 32 of 33 (97%) LITAs. Eight (25%) adhered to the sternum, 6 (19%) adhered to the chest wall, and 1 (3%) crossed the midline. A single right ITA injury (3%) was adherent to the sternum. Twelve (36%) were managed by primary suturing and the remaining with complex reconstructions. Occurrence of major complications was similar between groups 1 and 2. Postoperative assist devices, including intra-aortic balloon pumps (7/1762 [0.40%] vs 6/1762 [0.34%], P = .78), were used infrequently. Operative mortality was 3.4% (57/1666) in group 1 and 3.2% (52/1626) in group 2 (P = .72) - 3.1% (1/32) among those with an injured patent ITA-LAD versus 3.4%(56/1634) without injury (P > .99). CONCLUSIONS: Redo CABG with a patent ITA-LAD is technically demanding and carries risk of ITA injury. Graft adherence to the sternum or chest wall is a particular risk, often related to conduct of the primary operation. With careful planning, reoperation can be performed safely in select patients with effective operative strategies and techniques.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Alaraj R, Alshneikat M, Awad AK, et al. Is a patent internal thoracic artery-to-left anterior descending artery still a risk factor in patients undergoing isolated redo coronary artery bypass grafting? J Thorac Cardiovasc Surg. 2026. PMID: 42092509. doi:10.1016/j.jtcvs.2026.04.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。