文献速递先天性心脏病外科主动脉外科

新生儿主动脉弓手术中循环停搏与选择性顺行脑灌注的当代国际实践调查

Contemporary Use of Circulatory Arrest and Selective Antegrade Cerebral Perfusion During Neonatal Aortic Arch Surgery-International Survey.
PubMed 文献 · Ann Thorac Surg · 2026-04-13

结果显示69.2%仅使用选择性顺行脑灌注(SACP),9.6%仅使用深低温循环停搏(DHCA),21.2%根据解剖或预计停搏时间选择;41%的受访者改变了个人实践,多从DHCA转向SACP。SACP的目标温度、流量确定和监测策略存在显著差异。

要点

  • 多数先天性心脏病外科医生在新生儿主动脉弓手术中仅使用SACP,但具体实践差异大。
  • 41%的受访者改变了个人实践,多从DHCA转向SACP,尤其年长医生。
  • SACP的目标温度、流量计算和监测方法缺乏统一标准。

核心结论

  • 新生儿主动脉弓修复中的神经保护策略存在显著差异,强调需要基于证据的标准化和高保真神经监测策略。

主要发现

  • 69.2%的受访者仅使用SACP,9.6%仅使用DHCA,21.2%根据解剖或预计停搏时间选择。
  • 41%的受访者报告个人实践改变,多从DHCA转向SACP,尤其年长医生(中位年龄60 vs 48岁,P < .001)。
  • 使用SACP者中78.3%单独使用,21.7%联合下半身灌注;目标温度范围从<20 °C到35 °C,较长手术倾向于更低温度。
  • 流量确定方式多样:59.6%基于体重计算,其余根据压力或近红外光谱调整;启动后流量根据右桡动脉压力(38.0%)或近红外光谱(55.4%)滴定。

关键数值与推荐

  • SACP目标温度范围为<20 °C至35 °C,较长手术采用较低温度。
  • 59.6%的受访者使用基于体重的流量计算,38.0%根据右桡动脉压力滴定流量,55.4%根据近红外光谱滴定流量。

临床怎么用

  • 临床医生应了解新生儿主动脉弓手术中神经保护策略的多样性,并根据解剖和预计停搏时间个体化选择SACP或DHCA。
  • 在SACP中,需注意温度、流量计算和监测方法缺乏统一标准,应结合近红外光谱和压力监测进行精细化调整。

局限性

  • 研究为问卷调查,存在应答偏倚和回忆偏倚。
  • 样本量有限(104名外科医生),可能不能完全代表全球实践。
  • 未报告患者结局数据,无法评估不同策略与临床结果的关系。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Selective antegrade cerebral perfusion (SACP) is increasingly used during neonatal aortic arch surgery, yet practices remain inconsistent across surgeons and institutions due to limited evidence and lack of consensus. This study aimed to characterize deep hypothermic circulatory arrest (DHCA) and SACP practices among congenital heart surgeons internationally, including temperature, flow rate, and monitoring. METHODS: A 124-question electronic survey was distributed to congenital heart surgeons worldwide through the World Society for Pediatric and Congenital Heart Surgery from November 2024 to February 2025. Responses were limited to currently practicing or recently retired surgeons. RESULTS: The survey was completed by 104 surgeons (95.2% active, 4.8% retired). Respondents were predominantly men (93.3%) with a median age of 53 years and 19 years in practice. SACP was used exclusively by 69.2% and DHCA by 9.6%, whereas 21.2% selected between techniques based on anatomy or anticipated arrest duration. A change in individual practice was reported by 41% of the respondents, most transitioning from DHCA to SACP-particularly among older surgeons (median age 60 vs 48 years, P < .001). Among those using SACP, 78.3% used it alone and 21.7% combined it with lower body perfusion. Target SACP temperature ranged widely from <20 °C to 35 °C, with lower targets for longer procedures. Flow determination also varied: 59.6% used weight-based calculations, whereas others adjusted by pressure or near-infrared spectroscopy. After initiation, flow was titrated to right radial artery pressure (38.0%) or near-infrared spectroscopy (55.4%). CONCLUSIONS: Substantial variability persists in neuroprotective strategies during neonatal aortic arch repair, emphasizing the need for evidence-based standardization and high-fidelity neuromonitoring strategies.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Catalano MA, Toubat O, Jacobs JP, et al. Contemporary Use of Circulatory Arrest and Selective Antegrade Cerebral Perfusion During Neonatal Aortic Arch Surgery-International Survey. Ann Thorac Surg. 2026. PMID: 41985602. doi:10.1016/j.athoracsur.2026.03.064

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。