窦部折叠术治疗二叶式主动脉瓣修复的早期血流动力学结果
本研究评估窦部折叠术(SP)在非对称性二叶式主动脉瓣(BAV)修复中避免狭窄的血流动力学效果。2018至2023年,41例中重度主动脉瓣反流患者接受修复,其中14例行SP。术后1年SP组跨瓣峰值压差和最大流速均低于非SP组,但校正协变量后组间变化百分比无显著差异。结论认为SP可能与较低跨瓣峰值压差和最大流速相关,或有助于增强BAV修复后的血流动力学稳定性。
要点
- SP组术后1年跨瓣峰值压差和最大流速低于非SP组。
- 校正协变量后两组峰值压差和最大流速变化百分比无显著差异。
- 两组术后1年无死亡,反流控制良好且左室逆重构充分。
核心结论
- 在BAV修复中,SP可能与术后1年较低的跨瓣峰值压差和最大流速相关,提示其可能增强血流动力学稳定性。
研究设计与样本
- 回顾性队列研究,纳入2018至2023年41例中重度主动脉瓣反流并接受BAV修复的患者,SP组14例,非SP组27例。
主要发现
- 两组术后1年内均无死亡,反流控制良好且左室逆重构充分。
- 术后1年SP组跨瓣峰值压差为17.7 ± 5.5 mmHg(变化-8.8% ± 1.1%),最大流速为1.9 ± 0.31 m/s(变化-13.1% ± 2.1%)。
- 术后1年非SP组跨瓣峰值压差为24.7 ± 9.6 mmHg(变化+8.8% ± 1.3%),最大流速为2.58 ± 0.62 m/s(变化+9.3% ± 2.5%)。
- 校正协变量后,两组跨瓣峰值压差和最大流速的变化百分比无明确差异。
临床怎么用
- 对于非对称性BAV修复,可考虑行窦部折叠术以减少术后跨瓣峰值压差和最大流速,但需注意校正后差异不显著。
局限性
- 原文未明确报告研究局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Postoperative stenosis negatively affects durability after bicuspid aortic valve (BAV) valvuloplasty. This study was performed to evaluate the haemodynamic efficacy of sinus plication (SP) to avoid stenosis after asymmetrical BAV repair. METHODS: Between 2018 and 2023, 41 patients with BAV (33.3 ± 11.5 years, 40 males) with moderate-severe aortic regurgitation (AR) underwent aortic valve repair with (SP group, n = 14) or without (NSP group, n = 27) SP. SP was performed to reduce the circumference of the fused sinus and restore sinus contour symmetry. Preoperative and postoperative haemodynamic parameters were assessed at discharge and 1 year using transthoracic echocardiography. RESULTS: No deaths occurred within 1 year after surgery in either group. AR was well controlled and adequate left ventricular reverse remodelling was observed in both the groups up to 1 year postoperatively. At 1 year, lower transvalvular peak pressure gradient (PG) and maximum transvalvular flow velocity (Vmax) were observed in the SP group (peak PG: 17.7 ± 5.5 mmHg; % change -8.8% ± 1.1%, Vmax: 1.9 ± 0.31 m/s; % change -13.1% ± 2.1%) compared with the NSP group (peak PG: 24.7 ± 9.6 mmHg; +8.8% ± 1.3%, Vmax: 2.58 ± 0.62 m/s; +9.3% ± 2.5%), while there were no clear differences in % changes of peak PG or Vmax between the groups after adjustment for covariates. CONCLUSIONS: In BAV repair, SP was potentially associated with lower peak PG and Vmax at 1 year. These findings suggest that SP may enhance haemodynamic stability in BAV repair.
引用
- Maeda K, Ichihara N, Baba T, et al. Haemodynamic Early Outcomes of Sinus Plication for Bicuspid Aortic Valve Repair. Interdiscip Cardiovasc Thorac Surg. 2026. PMID: 41967860. doi:10.1093/icvts/ivag103
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。