全州质量协作推动冠状动脉搭桥中多动脉移植的应用
密歇根胸心血管外科医师协会质量协作自2016年实施质量改进项目以提升多动脉移植(MAG)在孤立性冠状动脉搭桥(CABG)中的应用。本研究更新该全州质量项目并评估MAG的安全性。结果显示MAG使用率从2014年的7.5%增至2023年的39.9%(P < .001),MAG术后手术死亡率的观察值与期望值比值为1.11(95% CI,0.97-1.3),未增加死亡风险。
要点
- 全州协作质量改进项目使MAG使用率从2014年7.5%升至2023年39.9%。
- MAG术后手术死亡率O/E比为1.11(95% CI 0.97-1.3),无死亡风险增加。
- 该协作模式可作为全国推广MAG的范本。
核心结论
- 全州外科医生主导的协作质量改进持续推动密歇根州孤立性CABG中MAG的应用。
- 过去十年MAG使用未增加手术死亡率,支持其安全用于常规实践。
研究设计与样本
- MAG定义为使用≥2支动脉导管,可伴或不伴额外静脉移植血管。
- 年度趋势采用Cochran-Armitage趋势检验分析,术后结局按胸外科医师学会定义以观察值与期望值比值及自助法95% CI报告。
主要发现
- MAG使用率从2014年的7.5%上升至2023年的39.9%(P < .001)。
- MAG术后手术死亡率的观察值与期望值比值为1.11(95% CI,0.97-1.3),表明无死亡风险增加。
临床怎么用
- 在心外科实践中可安全推广MAG作为常规血运重建策略,无需担心手术死亡率增加。
- 借鉴全州协作质量改进模式以促进MAG的广泛采纳。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The Michigan Society of Thoracic and Cardiovascular Surgeons Quality Collaborative implemented a quality improvement initiative in 2016 to increase multiarterial graft (MAG) use during isolated coronary artery bypass grafting (CABG). This initiative was associated with a marked increase in MAG use compared with historical rates, from 7.4% at baseline to 21.7% in 2019. The present study provides an update on this statewide quality initiative and assesses the safety of MAG with respect to operative mortality and major morbidity as MAG increasingly becomes the default revascularization strategy. METHODS: We queried the statewide database to identify adults undergoing primary CABG with the internal thoracic artery and at least 1 additional graft between January 1, 2014, and December 31, 2023. MAG was defined as the use of ≥2 arterial conduits, with or without additional venous grafts. Annual trends were analyzed using the Cochran-Armitage trend test. Postoperative outcomes, based on The Society of Thoracic Surgeons definitions, were reported as observed-to-expected ratios with bootstrapped 95% CIs. RESULTS: MAG use increased from 7.5% in 2014 to 39.9% in 2023 (P < .001). The observed-to-expected ratio for operative mortality after MAG was 1.11 (95% CI, 0.97-1.3), indicating no increased risk of death associated with MAG. CONCLUSIONS: Statewide surgeon-led collaborative quality improvement efforts continue to drive MAG adoption in isolated CABG operations in Michigan. MAG use was not associated with increased operative mortality over the past decade, supporting its safe implementation in routine practice. This statewide quality collaborative experience may serve as model to scale adoption of MAG nationally.
引用
- Topcu AC, He C, Clark MJ, et al. Statewide Quality Collaborative As a Forum for Change: Promoting Adoption of Multiarterial Grafting in Coronary Artery Bypass Graft Surgery. Ann Thorac Surg. 2026. PMID: 42035976. doi:10.1016/j.athoracsur.2026.04.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。