文献速递冠心病外科

对角支吻合角度对序贯冠状动脉旁路移植术后心脏结局的影响

Impact of Diagonal Branch Angle on Cardiac Outcomes After Sequential Coronary Bypass Surgery.
PubMed 文献 · Interdiscip Cardiovasc Thorac Surg · 2026-01-01

该回顾性研究纳入197例接受LITA-LAD及顺时针RITA-RA I型复合序贯桥的孤立CABG患者,按对角支吻合角度(D-angle)分为窄角组(≤90°,n=16)和宽角/无对角支吻合组(n=181)。

要点

  • 窄D-angle(≤90°)与序贯桥不良事件风险升高独立相关(校正HR 4.3)。
  • 窄角组免于序贯桥不良事件率1/5/10年均为74.0%,显著低于宽角组。
  • 全因死亡和不良心脏事件率两组无显著差异。

研究设计与样本

  • 回顾性研究,纳入2010-2023年197例接受孤立CABG并使用LITA-LAD及顺时针RITA-RA I型复合序贯桥的患者。
  • 按D-angle分为窄角组(≤90°,n=16)和宽角/无对角支吻合组(n=181)。
  • 中位随访5.7年(范围3.2-9.1年)。

主要发现

  • 两组年龄、男性比例、糖尿病、三支病变、非体外循环CABG比例无显著差异。

关键数值与推荐

  • D-angle≤90°定义为窄角,>90°或无对角支吻合为宽角。
  • 免于序贯桥不良事件率:窄角组1/5/10年均为74.0%,宽角组为93.6%/92.0%/92.0%。

临床怎么用

  • 在序贯桥吻合对角支时,应尽量避免形成≤90°的窄角,以降低序贯桥不良事件风险。
  • 对已采用窄D-angle吻合的患者,术后需加强序贯桥通畅性监测。

局限性

  • 回顾性单中心设计,窄角组样本量小(n=16),可能存在选择偏倚。
  • 宽角组包含无对角支吻合患者,可能影响组间比较。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To evaluate whether the diagonal branch anastomotic angle (D-angle) influences outcomes following coronary artery bypass grafting (CABG). METHODS: This study retrospectively examined 197 patients who underwent isolated CABG between 2010 and 2023 using left internal thoracic artery (LITA)-left anterior descending artery (LAD) grafting and clockwise right ITA (RITA)-radial artery (RA) I-composite sequential grafts. Patients were categorized into Narrow (D-angle ≤ 90°, n = 16) and Wide (D-angle > 90° or without diagonal anastomosis, n = 181) groups. RESULTS: Mean age was 69 ± 10 and 65 ± 10 years in the Narrow and Wide groups, respectively (P = .107). Male sex (93.8% vs 91.2%), diabetes (68.8% vs 57.5%), 3-vessel disease (75.0% vs 85.1%), and off-pump CABG (68.8% vs 76.2%) values were similar; however, the Narrow group had more anastomoses (4.2 ± 0.8 vs 3.4 ± 0.7, P < .001). Median follow-up was 5.7 years [3.2-9.1]. Rates of all-cause mortality and adverse cardiac events did not differ significantly (P = .193; P = .074). However, freedom from adverse sequential graft events was lower in the Narrow group, with 1-, 5-, and 10-year estimates of 74.0%, 74.0%, and 74.0%, compared with 93.6%, 92.0%, and 92.0% in the Wide group, respectively (log-rank P = .008). Narrow D-angle remained an independent predictor in multivariate analysis (adjusted hazard ratio, 4.3; 95% confidence interval, 1.3-13.7; P = .014). CONCLUSIONS: A narrow D-angle was independently associated with increased incidence of adverse sequential graft events.

来源:Interdiscip Cardiovasc Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Ohtani A, Yajima S, Yoshioka D, et al. Impact of Diagonal Branch Angle on Cardiac Outcomes After Sequential Coronary Bypass Surgery. Interdiscip Cardiovasc Thorac Surg. 2026. PMID: 41984816. doi:10.1093/icvts/ivag101

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。