对角支吻合角度对序贯冠状动脉旁路移植术后心脏结局的影响
该回顾性研究纳入197例接受LITA-LAD及顺时针RITA-RA I型复合序贯桥的孤立CABG患者,按对角支吻合角度(D-angle)分为窄角组(≤90°,n=16)和宽角/无对角支吻合组(n=181)。
要点
- 窄D-angle(≤90°)与序贯桥不良事件风险升高独立相关(校正HR 4.3)。
- 窄角组免于序贯桥不良事件率1/5/10年均为74.0%,显著低于宽角组。
- 全因死亡和不良心脏事件率两组无显著差异。
研究设计与样本
- 回顾性研究,纳入2010-2023年197例接受孤立CABG并使用LITA-LAD及顺时针RITA-RA I型复合序贯桥的患者。
- 按D-angle分为窄角组(≤90°,n=16)和宽角/无对角支吻合组(n=181)。
- 中位随访5.7年(范围3.2-9.1年)。
主要发现
- 两组年龄、男性比例、糖尿病、三支病变、非体外循环CABG比例无显著差异。
关键数值与推荐
- D-angle≤90°定义为窄角,>90°或无对角支吻合为宽角。
- 免于序贯桥不良事件率:窄角组1/5/10年均为74.0%,宽角组为93.6%/92.0%/92.0%。
临床怎么用
- 在序贯桥吻合对角支时,应尽量避免形成≤90°的窄角,以降低序贯桥不良事件风险。
- 对已采用窄D-angle吻合的患者,术后需加强序贯桥通畅性监测。
局限性
- 回顾性单中心设计,窄角组样本量小(n=16),可能存在选择偏倚。
- 宽角组包含无对角支吻合患者,可能影响组间比较。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To evaluate whether the diagonal branch anastomotic angle (D-angle) influences outcomes following coronary artery bypass grafting (CABG). METHODS: This study retrospectively examined 197 patients who underwent isolated CABG between 2010 and 2023 using left internal thoracic artery (LITA)-left anterior descending artery (LAD) grafting and clockwise right ITA (RITA)-radial artery (RA) I-composite sequential grafts. Patients were categorized into Narrow (D-angle ≤ 90°, n = 16) and Wide (D-angle > 90° or without diagonal anastomosis, n = 181) groups. RESULTS: Mean age was 69 ± 10 and 65 ± 10 years in the Narrow and Wide groups, respectively (P = .107). Male sex (93.8% vs 91.2%), diabetes (68.8% vs 57.5%), 3-vessel disease (75.0% vs 85.1%), and off-pump CABG (68.8% vs 76.2%) values were similar; however, the Narrow group had more anastomoses (4.2 ± 0.8 vs 3.4 ± 0.7, P < .001). Median follow-up was 5.7 years [3.2-9.1]. Rates of all-cause mortality and adverse cardiac events did not differ significantly (P = .193; P = .074). However, freedom from adverse sequential graft events was lower in the Narrow group, with 1-, 5-, and 10-year estimates of 74.0%, 74.0%, and 74.0%, compared with 93.6%, 92.0%, and 92.0% in the Wide group, respectively (log-rank P = .008). Narrow D-angle remained an independent predictor in multivariate analysis (adjusted hazard ratio, 4.3; 95% confidence interval, 1.3-13.7; P = .014). CONCLUSIONS: A narrow D-angle was independently associated with increased incidence of adverse sequential graft events.
引用
- Ohtani A, Yajima S, Yoshioka D, et al. Impact of Diagonal Branch Angle on Cardiac Outcomes After Sequential Coronary Bypass Surgery. Interdiscip Cardiovasc Thorac Surg. 2026. PMID: 41984816. doi:10.1093/icvts/ivag101
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。