CT测量的瓣环尺寸在经导管二尖瓣置换术中的多中心注册研究
该研究基于多中心TENDER注册(NCT04898335)的145例TMVR患者,分析术前4D-CT瓣环尺寸与心脏及全因死亡的关系。1年全因死亡率为24.8%,心脏死亡率为5.5%;心脏死亡者瓣环参数显著更大,瓣环面积损失亦更大,提示较大瓣环尺寸和瓣环面积损失可能预测1年心脏死亡。
要点
- TMVR术后1年全因死亡率24.8%,心脏死亡率5.5%。
- 心脏死亡者收缩期和舒张期瓣环前后径、周长及面积均显著更大。
核心结论
- 较大的瓣环尺寸和较大的瓣环面积损失可能预测TMVR术后1年心脏死亡。
研究设计与样本
- 多中心TENDER注册(NCT04898335)的子分析,纳入145例TMVR患者,评估术前4D-CT瓣环尺寸与心脏及全因死亡的相关性。
主要发现
- 1年全因死亡率为24.8%(36/145),心脏死亡率为5.5%(8/145)。
临床怎么用
- 术前CT综合评估瓣环尺寸可能有助于TMVR患者筛选和风险分层。
- 较大瓣环尺寸及瓣环面积损失较大者需警惕1年心脏死亡风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Transcatheter mitral valve replacement (TMVR) is a preferred interventional option for high-risk patients with severe mitral regurgitation who are ineligible for transcatheter edge-to-edge repair. However, the role of annular dimensions in risk stratification has been marginally explored in this distinct anatomical setting with preserved native leaflets in patients with varying degree of myocardial damage. METHODS: This subanalysis of the multicenter TENDER registry (NCT04898335) included 145 TMVR patients. Preprocedural 4D-computed tomography-derived annular dimensions were evaluated for associations with cardiac and all-cause mortality. RESULTS: At 1 year, all-cause mortality was 24.8% (n = 36 of 145) and cardiac mortality was 5.5% (n = 8 of 145). Cardiac deaths were associated with significantly larger annular parameters, including systolic and diastolic anteroposterior diameter (32.8 ± 2.3 mm vs 29.9 ± 3.5 mm, P = .023; 33.2 ± 2.5 mm vs 30.3 ± 3.4 mm, P = .018), systolic and diastolic annular perimeter (126.1 ± 9.5 mm vs 115.8 ± 10.5 mm, P = .008; 125.6 ± 10.4 mm vs 115.8 ± 12.7 mm, P = .034), and annular area (1271.7 ± 193.2 mm2 vs 1076.2 ± 193.6 mm2, P = .006; 1262.7 ± 209.9 mm2 vs 1087.2 ± 194.7 mm2, P = .015). Annular area loss, calculated as the difference between native diastolic mitral annular area and the geometric effective orifice area of the implanted valve, was significantly greater in patients who died for cardiac reasons (999.72 ± 225.72 mm2) compared with survivors (826.68 ± 189.45 mm2; P = .022; odds ratio, 1.005, P = .030). CONCLUSIONS: Larger annular dimensions and greater annular area loss may predict 1-year cardiac death. Possible mechanisms include impaired left ventricle filling, artificial inflow-related outflow tract obstruction, and limited reverse remodeling. Comprehensive annular assessment may also enhance patient selection for future transseptal TMVR systems.
引用
- Zillner L, Wild MG, Hell MM, et al. CT-Based Annular Dimensions in Transcatheter Mitral Valve Replacement: A Multicenter Registry Study. Ann Thorac Surg. 2026. PMID: 41865959. doi:10.1016/j.athoracsur.2026.03.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。