文献速递瓣膜外科

术中经食管超声多平面重建测量二尖瓣环与左回旋支冠状动脉距离

Measurement of the Distance between the Mitral Annulus and the Left Circumflex Coronary Artery Using Multiplanar Reconstruction of Intraoperative Transoesophageal Echocardiography Images.
PubMed 文献 · Interdiscip Cardiovasc Thorac Surg · 2026-01-01

单中心回顾性队列纳入54例2020年1月至2021年7月因二尖瓣反流行二尖瓣修复术患者,用术中TEE图像多平面重建测量二尖瓣环与LCX距离(ML距离),并探索其与二尖瓣环分离(MAD)的关联。结果显示LCX在前后轴逆时针70-90度处距二尖瓣环最近,MAD组最小ML距离显著短于无MAD组(3.2[1.1]mm vs 4.9[2.1]mm),70-100度处差异显著。

要点

  • LCX距二尖瓣环最近处位于前后轴逆时针70-90度。
  • MAD组最小ML距离显著短于无MAD组(3.2 vs 4.9 mm)。
  • 术中TEE多平面重建可微创识别ML距离较短患者。

核心结论

  • 术中TEE多平面重建是识别ML距离较短患者的微创有用工具。
  • 二尖瓣环与LCX最近区域靠近前外侧交界,MAD患者尤甚。

研究设计与样本

  • 单中心回顾性队列研究,纳入54例2020年1月至2021年7月因二尖瓣反流行二尖瓣修复术患者。
  • 用术中TEE图像多平面重建测量ML距离,探索性比较MAD组(N=11)与无MAD组(N=43)。

主要发现

  • LCX在前后轴逆时针70-90度处距二尖瓣环最近,未观察到LCX损伤病例。
  • MAD最常见于P1,MAD组所有患者均有P1处分离。
  • MAD组最小ML距离显著短于无MAD组(3.2[1.1]mm vs 4.9[2.1]mm)。
  • 总体ML距离MAD组短于无MAD组,70-100度处显著缩短。

临床怎么用

  • 二尖瓣修复术前可用术中TEE多平面重建评估ML距离,辅助识别LCX损伤高风险患者。

局限性

  • 单中心回顾性研究,样本量54例,MAD组仅11例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: We aimed to describe the anatomical distance between the mitral annulus and the left circumflex coronary artery (LCX) using multiplanar reconstruction (MPR) of transoesophageal echocardiography (TEE) images and to investigate its association with mitral annular disjunction (MAD). METHODS: A single-centre retrospective cohort study included 54 patients who underwent mitral valve repair for mitral regurgitation between January 2020 and July 2021. We measured the distance between the mitral annulus and the LCX (ML distance) using MPR of intraoperative TEE images. As an exploratory analysis, we compared the ML distance between patients with MAD (group D: N = 11) and those without (group N: N = 43). RESULTS: The LCX was closest to the mitral annulus at 70-90 degrees counterclockwise from the anteroposterior axis. No cases of LCX injury were observed. MAD was most frequently observed at P1, and all patients in group D had disjunction at P1. The minimum ML distance was significantly shorter in group D than in group N (3.2 [1.1] mm in group D, and 4.9 [2.1] mm in group N). Overall, the ML distance was shorter in group D than in group N, and was significantly shorter at 70-100 degrees. CONCLUSIONS: MPR of intraoperative TEE images is a less invasive and useful tool to detect patients with a short ML distance. The area of the closest distance from the mitral annulus to the LCX is near the anterolateral commissure, especially in patients with MAD.

来源:Interdiscip Cardiovasc Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Kuroda Y, Soga Y, Matsuo T, et al. Measurement of the Distance between the Mitral Annulus and the Left Circumflex Coronary Artery Using Multiplanar Reconstruction of Intraoperative Transoesophageal Echocardiography Images. Interdiscip Cardiovasc Thorac Surg. 2026. PMID: 41564307. doi:10.1093/icvts/ivag022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。