文献速递瓣膜外科

二尖瓣手术中自动缝线固定技术的长期结局:能否减少人工瓣膜裂开?

Automated Suture Securing Technology in Mitral Valve Surgery: A Strategy to Reduce Prosthetic Dehiscence?
PubMed 文献 · Eur J Cardiothorac Surg · 2026-01-01

主要终点为需再干预的人工瓣膜裂开。结果显示自动钛紧固装置组人工瓣膜裂开风险显著低于手工打结组(校正sHR 0.34;95%CI 0.12-0.91;

要点

  • 自动钛紧固装置与二尖瓣手术后人工瓣膜裂开风险降低相关(校正sHR 0.34)。
  • 自动钛紧固装置不增加缺血性卒中、颅内出血或全因死亡风险。
  • 因裂开事件数有限且存在残余混杂,结果需谨慎解读。

核心结论

  • 自动钛紧固装置的使用似乎与二尖瓣手术中较低的人工瓣膜裂开风险相关。

主要发现

  • 1072例(40%)使用自动钛紧固装置,1606例(60%)使用传统手工打结缝线。
  • 随访期间共31例(1.2%)发生人工瓣膜裂开。

临床怎么用

  • 在二尖瓣修复或置换术中,可考虑使用自动钛紧固装置替代手工打结以降低人工瓣膜裂开风险,但需结合患者个体情况并注意证据局限性。

局限性

  • 人工瓣膜裂开事件数量有限。
  • 回顾性设计存在残余混杂可能。
  • 结果为单中心研究,外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: This study aimed to assess long-term outcomes of automated titanium fasteners versus hand-tied knots in mitral valve surgery. METHODS: In this retrospective, single-centre analysis, 2678 adult patients who underwent mitral valve repair or replacement between November 2008 and November 2024 at the Medical University of Vienna were included. Patients were grouped according to the suture-securing technique used: automated titanium fasteners versus hand-tied knots. The primary endpoint was prosthetic dehiscence (either mitral annuloplasty ring or valve replacement prosthesis) requiring reintervention. Secondary endpoints comprised ischaemic stroke, intracranial bleeding, and all-cause mortality during the follow-up period. RESULTS: Among the study population, 1072 (40%) underwent mitral valve surgery using an automated titanium fastener device, and 1606 (60%) with conventional hand-tied sutures. A total of 31 patients (1.2%) had prosthetic dehiscence during the follow-up period. The risk of prosthetic dehiscence was significantly lower in the automated titanium fastener group in both univariable (crude sub-hazard ratio [sHR] 0.32; 95% confidence interval [CI], 0.12-0.86, P = .023) and multivariable competing risk regression analysis (adjusted sHR 0.34; 95% CI, 0.12-0.91, P = .033). Automated titanium fastener group was not associated with an increased risk of ischaemic stroke (adjusted sHR 0.92; 95% CI, 0.67-1.27, P = .600), intracranial bleeding (adjusted sHR 0.89; 95% CI, 0.52-1.52, P = .675), or all-cause mortality (adjusted hazard ratio 0.93; 95% CI, 0.74-1.18, P = .559). CONCLUSIONS: The use of an automated titanium fastener device seems to be associated with a lower risk of prosthetic dehiscence in mitral valve surgery. Due to the limited number of prosthetic dehiscence events and the potential for residual confounding, the results should be interpreted with caution.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。

引用

  1. Kahrovic A, Herkner H, Werner P, et al. Automated Suture Securing Technology in Mitral Valve Surgery: A Strategy to Reduce Prosthetic Dehiscence? Eur J Cardiothorac Surg. 2026. PMID: 41512298. doi:10.1093/ejcts/ezag013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。