Gore胸部分支内假体欧洲单中心初步经验
本研究回顾性分析2024至2025年单中心20例胸主动脉分支内假体(TBE)植入病例,用于主动脉弓及降主动脉病变。技术结果满意,无院内及30天死亡,但2例术后7-8周猝死。需更长随访和更大样本验证。
要点
- TBE保留左锁骨下动脉17例、无名动脉2例、左颈动脉1例。
- 术后6周CT血管造影显示所有支架位置理想且分支通畅。
- 无院内及30天死亡,但2例术后7-8周不明原因猝死。
核心结论
- GORE TBE用于多种主动脉弓或降主动脉病变技术结果满意,但需更长随访和更大样本验证。
研究设计与样本
- 回顾性队列分析,纳入2024至2025年单中心20例接受TBE治疗的主动脉弓及降主动脉病变患者。
主要发现
- 20例均成功植入TBE,分支用于保留左锁骨下动脉17例、无名动脉2例、左颈动脉1例。
- 中位随访6(1-12)个月,术后6周CT血管造影显示所有支架位置理想且分支通畅。
- 无院内或30天死亡,但2例分别于术后7周和8周不明原因猝死,6周CT血管造影未见异常。
临床怎么用
- TBE可作为保留主动脉弓分支的胸主动脉腔内修复选择,用于囊状弓部动脉瘤、慢性B型夹层扩张等病变。
- 术后需关注迟发死亡风险,即使早期影像学正常也应加强随访。
局限性
- 回顾性单中心小样本(20例),随访时间短(中位6个月)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To report an initial experience with a novel off-the-shelf single branched thoracic aortic stent graft preserving various aortic arch vessels. METHODS: Our study is a retrospective cohort analysis of the largest European case series to date. We treated twenty patients for various aortic arch and descending pathology in the year 2024 and 2025. RESULTS: Twenty patients underwent successful implantation of the thoracic branched endoprosthesis (TBE) in the aortic arch and descending thoracic aorta. The sidebranch was applied to preserve the left subclavian artery in 17 patients, the innominate artery in two and the left carotid artery in one patient. Patients were treated for saccular arch aneurysms, chronic type B dissections with progressive dilatation, type 1a endoleaks after TEVAR, degenerative thoracic aneurysms, localized type A dissections or a first stage Crawford type II thoraco-abdominal aneurysm repair followed by a subsequent visceral branched endoprosthesis. The median follow-up period was six (1-12) months and technical results were satisfying. All TBE stentgrafts were implanted in the desired position with a patent branch on computed tomography angiography (CT-A) scan six weeks postoperatively. There was no in-hospital or 30-day mortality. Unfortunately, two patients suddenly died seven and eight weeks postoperatively of unknown causes. CT-A scan at six weeks showed no abnormalities concerning the aorta or TBE in both patients. CONCLUSIONS: The present study demonstrates satisfying technical results with the GORE TBE which was successfully implanted for multiple indications of aortic arch or descending pathology. Longer follow-up and larger series are needed for verification.
引用
- Dirven M, Geuzebroek GSC, Nauta FJH, et al. An Initial Single-Center European Experience with the Gore Thoracic Branch Endoprosthesis. Interdiscip Cardiovasc Thorac Surg. 2026. PMID: 41453138. doi:10.1093/icvts/ivaf309