机器人辅助微创升主动脉置换:解剖模型可行性研究
本研究在6个猪胸腔器官包和2具人类尸体模型上,由经验丰富的机器人外科医生和一名外科住院医师使用DaVinci 5机器人平台完成机器人辅助升主动脉置换。所有模型均植入Dacron人工血管,猪模型远端和近端吻合时间分别为10.7分钟(SD=4.5)和9.7分钟(SD=3.2),尸体模型为13.3分钟(SD=2.0)和12.3分钟(SD=1.9)。结论认为该技术在解剖模型上技术可行,吻合时间合理,可能适合临床场景。
要点
- 机器人辅助升主动脉置换在猪器官包和人类尸体模型上均技术可行。
- 猪模型远端和近端吻合时间分别为10.7分钟和9.7分钟。
- 尸体模型273针缝合中仅4处出现缝隙,猪模型无缝隙。
核心结论
- 机器人升主动脉置换在解剖模型上技术可行,吻合时间合理,可能适合临床场景。
研究设计与样本
- 实验研究,在6个猪胸腔器官包和2具人类尸体模型上由经验丰富的机器人外科医生和一名外科住院医师完成手术。
主要发现
- 猪模型远端和近端吻合时间分别为10.7分钟(SD=4.5)和9.7分钟(SD=3.2)。
- 尸体模型远端和近端吻合时间分别为13.3分钟(SD=2.0)和12.3分钟(SD=1.9)。
- 猪模型缝合对齐无缝隙,尸体模型273针中4针出现缝隙。
临床怎么用
- 该技术可能为升主动脉置换提供微创机器人选项,但需进一步临床验证。
局限性
- 研究仅基于动物和尸体模型,样本量小,未在活体或临床中验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Robotic cardiac surgery is well established in mitral valve repair and coronary artery bypass grafting. Outside of limited applications addressing the abdominal aorta, robotic technology is rarely utilized in vascular surgery. Robotic replacement of the ascending aorta has not yet been described. The aim of this experimental study was to establish the fundamental surgical techniques for robotically assisted replacement of the ascending aorta. METHODS: Robotic ascending aortic replacement was performed in 6 porcine thoracic organ packs and 2 human cadaver models by an experienced robotic surgeon and a surgical resident. All essential steps of the procedure were performed utilizing the DaVinci 5 robotic platform. Dacron grafts were implanted after ascending aorta resection in all models. Operative times and comfort level were recorded for each step of the procedure. RESULTS: Robotically assisted ascending aortic replacement was deemed feasible in all porcine and human cadaveric simulations. Distal and proximal anastomoses in the porcine organ block were completed in 10.7 (SD = 4.5) and 9.7 minutes (SD = 3.2), respectively. Anastomotic times were slightly longer in the cadaveric model at 13.3 (SD = 2.0) and 12.3 minutes (SD = 1.9). No gaps in suture alignment were noted in the porcine organ model, whereas 4 gaps out of 273 stitches in the human cadaveric model were observed. CONCLUSIONS: Robotic replacement of the ascending aorta is technically feasible in anatomical models with reasonable anastomotic times, which may be suitable for the clinical setting. Robotic suturing on the ascending aorta can be performed with accuracy and efficiency.
引用
- Fisher BW, Stein H, Greenberg O, et al. Robotically Assisted, Minimally Invasive Ascending Aortic Replacement: A Feasibility Study in Anatomical Models. Eur J Cardiothorac Surg. 2026. PMID: 41428447. doi:10.1093/ejcts/ezaf470