术前掌弓血流速度与桡动脉 harvest 后手部缺血症状的关联
该回顾性研究纳入584例使用桡动脉行冠状动脉旁路移植术的患者,按术前超声掌弓反向流速分为正常、边缘和低速三组,发现术后30天缺血性手部症状总体发生率为5.8%,术前流速与症状无显著关联,仅糖尿病与症状风险增加相关。
要点
- 术前掌弓反向流速低不增加桡动脉 harvest 后手缺血风险。
- 术后30天缺血性手部症状发生率为5.8%,无需干预的缺血事件。
- 糖尿病与术后手部症状风险增加独立相关。
核心结论
- 术前双功超声显示掌弓反向流速低与桡动脉 harvest 后手缺血风险增加无关。
- 在尺侧侧支循环充分的前提下,边缘甚至低流速患者 harvest 桡动脉是安全的。
研究设计与样本
- 回顾性综述,纳入2016至2023年584例使用桡动脉行冠状动脉旁路移植术的患者。
- 根据术前双功超声桡动脉阻断时掌弓反向流速分组:正常(>20 cm/s)、边缘(10-20 cm/s)、低(<10 cm/s)。
主要发现
- 584例中421例(72.1%)为正常流速,139例(23.8%)为边缘流速,24例(4.1%)为低流速。
- 术后30天缺血性手部症状总体发生率为5.8%(34例)。
- 术前掌弓反向流速与术后症状无显著关联(边缘/低流速合并 vs 正常的比值比为1.56;95% CI,0.84-2.85)。
- 无需要干预的缺血事件发生。
- 多变量分析中仅糖尿病与症状风险增加相关(比值比1.98;95% CI,1.11-3.59)。
临床怎么用
- 术前双功超声评估掌弓反向流速可用于桡动脉 harvest 前评估,但低流速不构成禁忌。
- 对于边缘或低流速患者,若尺侧侧支循环充分,可安全 harvest 桡动脉。
- 糖尿病患者术后应更关注手部缺血症状。
局限性
- 回顾性研究设计。
- 术后30天随访可能低估迟发缺血症状。
- 样本中低流速组仅24例,统计效能有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Duplex ultrasonography is often used to assess radial artery suitability for coronary artery bypass grafting, but clear guidelines for its usage are lacking. This study investigates the association between preoperative arterial velocity characteristics and postoperative ischemic hand symptoms after endoscopic radial artery harvest. METHODS: We performed a retrospective review of 584 patients who underwent coronary artery bypass grafting with a radial artery graft from 2016 to 2023. Using preoperative duplex ultrasonography, patients were categorized based on their palmar arch reversal velocity during radial artery occlusion: normal (>20 cm/s), marginal (10-20 cm/s), or low (<10 cm/s). The primary outcome was any report of ischemic hand symptoms (pain, weakness, or sensation loss) at the 30-day postoperative follow-up. RESULTS: Of the 584 patients, 421 (72.1%) had normal flow, 139 (23.8%) had marginal flow, and 24 (4.1%) had low flow. The overall incidence of ischemic hand symptoms at 30 days was low at 5.8% (34 patients). There was no significant association between preoperative palmar arch reversal velocity and postoperative symptoms (odds ratio, 1.56 for combined marginal/low flow vs normal; 95% CI, 0.84-2.85). No ischemic events requiring intervention occurred. On multivariable analysis, only diabetes was associated with an increased risk of symptoms (odds ratio, 1.98; 95% CI, 1.11-3.59). CONCLUSIONS: Low palmar arch reversal velocity on preoperative duplex ultrasonography was not associated with an increased risk of hand ischemia after radial artery harvest. These findings suggest that harvesting the radial artery is safe in patients with marginal or even low flow, provided ulnar collateral circulation is adequate.
引用
- Szeto JJ, Kurzan P, Lutfi W, et al. Association Between Preoperative Palmar Arch Velocity on Duplex Ultrasonography and Ischemic Hand Symptoms After Radial Artery Harvest. Ann Thorac Surg. 2025. PMID: 41265740. doi:10.1016/j.athoracsur.2025.11.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。