机器人心脏手术中左心耳闭合不全的CT影像特征
本研究回顾性分析125例在二尖瓣手术中使用达芬奇系统行连续聚丙烯缝线左心耳闭合的患者,其中100例术后接受心电图门控CT评估。完全闭合率76%,不全闭合率24%,不全闭合多位于二尖瓣交界或缝线起始处,呈特征性「气泡征」,且与三尖瓣修复及V1导联f波振幅低相关;24个月内两组卒中发生率相似。
要点
- 机器人直视下左心耳连续缝线闭合不全率仍达24%。
- 不全闭合CT呈「气泡征」,多见于二尖瓣交界或缝线起始处。
- 三尖瓣修复及V1导联f波振幅低与不全闭合相关。
核心结论
- 尽管机器人直视下操作,左心耳连续缝线闭合不全仍发生于24%的病例,解剖因素可能比技术本身影响更大。
研究设计与样本
- 回顾性分析125例在二尖瓣手术中经达芬奇系统行连续聚丙烯缝线左心耳闭合的患者,其中100例术后行心电图门控CT评估闭合完整性。
主要发现
- 100例术后CT中完全闭合76%,不全闭合24%,不全闭合多位于二尖瓣交界或缝线起始处并呈「气泡征」。
- 不全闭合与三尖瓣修复及V1导联f波振幅低相关,24个月内两组卒中发生率相似。
关键数值与推荐
- 完全闭合率76%,不全闭合率24%(n=100术后CT)。
- 不全闭合与三尖瓣修复及V1导联f波振幅低相关。
- 24个月内完全闭合与不全闭合组卒中发生率相似。
临床怎么用
- 术后心电图门控CT可用于识别左心耳不全闭合及「气泡征」。
- 对长期房颤高危患者,可考虑管腔压碎或外部夹闭等技术以提高闭合成功率。
局限性
- 回顾性设计,仅100例患者接受术后CT评估。
- 原文未报告单中心/多中心、随访完整度等细节。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: In atrial fibrillation (AF), surgical management of the left atrial appendage (LAA) is crucial to prevent stroke. However, incomplete closure poses a residual embolic risk. METHODS: We retrospectively analyzed patients who underwent LAA closure using a continuous polypropylene suture technique during mitral valve surgery with the da Vinci system. Closure completeness was assessed via electrocardiogram-gated computed tomography (CT), and 3 D imaging was used to localize incomplete sites. RESULTS: Of 125 patients, 100 underwent postoperative CT. Complete closure (cLAA) was achieved in 76%, while 24% had incomplete closure (iLAA), typically at the mitral valve junction or suture start. These showed a characteristic "speech bubble" appearance. iLAA was associated with tricuspid valve repair and low V1 f-wave amplitude. Stroke rates were similar between groups over 24 months. CONCLUSIONS: Incomplete LAA closure occurred in 24% of cases despite direct visualization using robotics. Anatomical factors likely contribute more than technique alone. For high-risk patients with long-standing AF, techniques such as lumen crushing or external clips may enhance closure success. Further refinements are needed to improve the reliability of internal LAA closure methods.
引用
- Nakayama T, Nakamura Y, Shukuya A, et al. Speech bubble sign - insights regarding incomplete left atrial appendage closure via electrocardiography-synchronized computed tomography in robotic surgery cases. Interdiscip Cardiovasc Thorac Surg. 2025. PMID: 41134183. doi:10.1093/icvts/ivaf172
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。