PubMed 文献 · J Thorac Cardiovasc Surg · 2025-09-29

该研究分析了3265例75岁及以下接受主动脉瓣置换术(伴或不伴冠状动脉旁路移植术)的患者,利用出院前超声测得的有效开口面积(EOA)及EOA指数(EOAi),通过自助法逻辑回归和限制性立方样条确定最佳生存截点,并用多变量Cox模型比较生物瓣与机械瓣的远期生存。结果显示,在EOA≥2 cm²或EOAi≥1.08 cm²/m²的患者中,生物瓣组远期死亡风险显著高于机械瓣组;而在较小EOA指标患者中无显著差异。

要点

  • 对于EOA<2 cm²或EOAi<1.08 cm²/m²的患者,生物瓣与机械瓣的远期生存无显著差异。

核心结论

  • 在较大瓣膜尺寸(EOA≥2 cm²或EOAi≥1.08 cm²/m²)患者中,机械瓣较生物瓣具有生存优势,而较小EOA指标患者中无此差异。

研究设计与样本

  • 回顾性队列研究,纳入3265例75岁及以下接受主动脉瓣置换术(伴或不伴冠状动脉旁路移植术)的患者。
  • EOA和EOAi取自出院前超声心动图,采用自助法逻辑回归和限制性立方样条确定生存截点,多变量Cox模型和调整Kaplan-Meier曲线分析生存。

关键数值与推荐

  • EOA截点为2 cm²,EOAi截点为1.08 cm²/m²。

临床怎么用

  • 对于瓣膜尺寸较大(EOA≥2 cm²或EOAi≥1.08 cm²/m²)的≤75岁主动脉瓣置换患者,选择机械瓣可能带来远期生存获益。
  • 对于EOA指标较小的患者,生物瓣与机械瓣的远期生存相似,瓣膜选择需综合其他因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We examined the potential influence of effective orifice area (EOA) and EOA index (EOAi) on survival between bioprosthetic and mechanical valves. METHODS: We analyzed 3265 patients aged 75 years or younger undergoing aortic valve replacement with or without coronary artery bypass grafting. EOA and EOAi were obtained from predischarge echocardiograms. Bootstrapped logistic regression and restricted cubic splines identified optimal survival cut points for EOA and EOAi. Multivariable Cox proportional hazards models were fitted, and adjusted Kaplan-Meier survival curves were generated using the identified EOA cut points. RESULTS: The mechanical aortic valve replacement group was younger (age 60 vs 69 years; P < .001). For mechanical and bioprosthetic aortic valve replacement groups, respectively, the median EOA was (2.0 cm2; range, 1.6-2.4 vs 2.1 cm2; range, 1.7-2.6 cm2; P < .001) and EOA index was (1.0 cm2/m2; range, 0.8-1.2 cm2/m2 vs 1.1 cm2/m2, range, 0.9-1.3 cm2/m2; P < .001) In patients with EOA ≥2 cm2, long-term adjusted risk of mortality was higher in the bioprosthesis group compared with the mechanical group (hazard ratio, 1.33; P = .010). However, no significant difference was observed for those with EOA <2 cm2 (hazard ratio, 1.01; 95% CI, 0.83-1.23; P = .932). Similarly, for EOA index ≥1.08 cm2/m2, the bioprosthesis group was associated with higher risk of long-term mortality (hazard ratio, 1.29; 95% CI, 1.01-1.64, P = .040), whereas no significant association was found for those with an EOA index <1.08 cm2/m2 (hazard ratio, 1.05; P = .621). CONCLUSIONS: In this cohort, there was a survival advantage of mechanical valves over bioprostheses in larger valve sizes but not in patients with smaller EOA metrics.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。