文献速递心外重症与机械循环支持

部分PTFE包裹降低LVAD移除心脏移植出血风险

Safe Practices: Partial Coverage of Left Ventricular Assist Device Reduces Bleeding Risk during Explant-Heart Transplant without Causing Obstruction.
PubMed 文献 · J Heart Lung Transplant · 2025-09-01

单中心研究探讨HeartMate 3植入时部分PTFE保护性包裹对移除-心脏移植围术期失血的影响。部分包裹流出道和底盘与减少术中及术后输血需求和胸管引流量显著相关,校正既往胸骨切开和多器官移植后仍成立。部分包裹不增加梗阻风险。

要点

  • 部分PTFE包裹可减少移除-心脏移植围术期输血和胸管引流量。
  • 部分包裹不增加流出道梗阻风险,有别于完全包裹。
  • 标准化LVAD植入技术有助于移植与非移植中心间连续性照护。

核心结论

  • HeartMate 3植入时部分PTFE包裹流出道和底盘与移除-心脏移植围术期输血需求及胸管引流量减少显著相关。

研究设计与样本

  • 单中心研究,比较HeartMate 3植入时部分PTFE保护性包裹对移除-心脏移植围术期失血的影响。

主要发现

  • 部分PTFE包裹与术中及术后输血需求减少显著相关。
  • 部分PTFE包裹与术后胸管引流量减少显著相关。
  • 校正既往胸骨切开和多器官移植后关联仍成立。
  • 部分PTFE包裹未增加流出道梗阻风险。

临床怎么用

  • HeartMate 3植入时可考虑部分PTFE包裹流出道和底盘以减少后续移除-心脏移植出血。
  • 标准化LVAD植入技术可促进移植与非移植中心间连续性照护。

局限性

  • 单中心研究,结论需多中心验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Left ventricular assist device (LVAD) explant is technically challenging during heart transplantation (HT) and is associated with intraoperative and postoperative blood loss. This single institution study examined the effects of partial polytetrafluoroethylene (PTFE) protective coverage during HeartMate 3 implant on perioperative blood loss during the explant-HT. We found that partial PTFE coverage of the outflow graft and chassis during HeartMate 3 implant is significantly associated with reduced intraoperative and postoperative transfusion requirements, and postoperative chest tube output. This association held true after adjusting for prior sternotomies and multi-organ transplants. While previous studies have warned against use of a complete PTFE wrap due to concerns of outflow graft obstruction, our data show that modification to a partial PTFE wrap could mitigate the bleeding risk without increasing the risk of obstruction. Standardization of LVAD implant technique across transplant and non-transplant centers can strengthen continuity of care and facilitate the explant-HT process.

来源:J Heart Lung Transplant,查看原文。版权归原作者所有。

引用

  1. Wang CC, Trahanas J, Petrovic M, et al. Safe Practices: Partial Coverage of Left Ventricular Assist Device Reduces Bleeding Risk during Explant-Heart Transplant without Causing Obstruction. J Heart Lung Transplant. 2025. PMID: 40902959. doi:10.1016/j.healun.2025.08.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。