文献速递肺外科

解剖性肺切除术后数字化胸腔引流负压设定随机多中心试验

Randomized Multicenter Trial of -8 cm H2O vs -15 cm H2O Intrathoracic Pressure Digital Thoracic Drainage for Air Leaks After Anatomic Pulmonary Resection.
PubMed 文献 · Ann Thorac Surg · 2025-08-29

该多中心随机对照试验纳入解剖性肺切除(肺段或肺叶切除)后中度漏气(100-1000 mL/min)患者,比较数字化胸腔引流系统-8 cm H2O与-15 cm H2O负压设定。主要终点持续性漏气发生率两组无显著差异(67.7% vs 60.4%;结论认为胸腔内负压设定不影响漏气早期缓解,可按患者状态在-8 cm H2O以上调整负压管理漏气。

要点

  • -8 cm H2O与-15 cm H2O组持续性漏气发生率无显著差异(67.7% vs 60.4%)。
  • 两组漏气持续时间、胸管置管时间及术后住院时间均相似。
  • 可按患者状态将负压调整在-8 cm H2O以上管理解剖性肺切除后漏气。

核心结论

  • 胸腔内负压设定(-8 cm H2O vs -15 cm H2O)未影响漏气的早期缓解。
  • 解剖性肺切除术后漏气可根据患者状态将负压调整在-8 cm H2O以上进行管理。

研究设计与样本

  • 多中心、前瞻性、随机对照试验,纳入肺段或肺叶切除术后中度漏气(100-1000 mL/min)患者。
  • 患者随机分入A组(生理压力模式,-8 cm H2O)与B组(-15 cm H2O)。
  • 共2379例登记患者中,A组93例、B组106例接受了分配治疗。

关键数值与推荐

  • 中度漏气定义为100-1000 mL/min。
  • A组负压设定为-8 cm H2O(生理压力模式),B组为-15 cm H2O。

临床怎么用

  • 解剖性肺切除术后中度漏气患者可采用-8 cm H2O负压设定,并根据患者状态调整在-8 cm H2O以上。
  • 负压设定选择不影响漏气缓解时间、置管时间及术后住院时间。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Digital pleural drainage systems are commonly used for chest tube management after lung resection, but the optimal intrathoracic pressure setting for digital pleural drainage systems in patients with air leaks remains unclear. METHODS: The study was a multicenter, prospective, randomized controlled trial including patients with moderate air leaks (100-1000 mL/min) after segmentectomy or lobectomy. Patients were randomized to group A (physiologic pressure mode, -8 cm H2O) and group B (-15 cm H2O). The primary end point was prolonged air leak incidence. RESULTS: Of 2379 registered patients, 93 in group A and 106 in group B received the assigned treatment. There was no significant difference in prolonged air leak incidence between the groups (67.7% vs 60.4%; P = .303). The duration of air leak (median, 6 vs 5 days; P = .429), chest tube placement (7 vs 7 days; P = .568), and postoperative hospital stay (median, 9 vs 9.5 days; P = .550) were similar. The frequency of pleurodesis due to air leak after postoperative day 5 was 43.0% in group A and 31.1% in group B (P = .105). The proportion of respiratory adverse events (grade 2 or higher) was 1.1% in group A and 6.6% in group B (P = .069). CONCLUSIONS: Intrathoracic pressure setting did not affect the earlier remission of air leaks. Air leaks after anatomic pulmonary resection may be appropriately managed by adjusting the negative intrathoracic pressure above -8 cm H2O according to the state of the patients.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Takamochi K, Endo M, Funai K, et al. Randomized Multicenter Trial of -8 cm H2O vs -15 cm H2O Intrathoracic Pressure Digital Thoracic Drainage for Air Leaks After Anatomic Pulmonary Resection. Ann Thorac Surg. 2025. PMID: 40886755. doi:10.1016/j.athoracsur.2025.07.056

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。