马凡综合征主动脉根部与升主动脉的生物力学特征

Biomechanics of the Aortic Root and Ascending Aorta in Patients With Marfan Syndrome.
PubMed 文献 · Eur J Cardiothorac Surg · 2025-01-01

本研究对马凡综合征(MFS)患者主动脉根部(n=10)和升主动脉(n=6)组织进行双轴拉伸与分层测试,并与正常主动脉、二叶式主动脉瓣(BAV)动脉瘤、三叶式主动脉瓣动脉瘤及A型夹层组织比较。结果显示MFS根部生物力学参数与其他组无统计学差异;升主动脉分层强度低于正常主动脉(31.9±8.5 vs 57.1±17.0 mN/mm,P=0.0003),能量损耗高于正常(0.071±0.017 vs 0.049±0.011,P=0.04),低应变模量低于BAV(75.0±11.0 vs 113.5±33.6 kPa,P=0.02)。结论认为MFS根部与升主动脉具有区别于正常及其他风险组的生物力学特征。

要点

  • MFS升主动脉分层强度显著低于正常主动脉,提示组织抗撕裂能力下降。
  • MFS升主动脉能量损耗高于正常、低应变模量低于BAV动脉瘤。
  • MFS根部能量损耗、低应变模量和分层强度与其他组无统计学差异。

核心结论

  • MFS的主动脉根部与升主动脉展现出区别于正常主动脉及其他风险组的生物力学特征。

研究设计与样本

  • 对MFS患者(根部10例、升主动脉6例)、BAV动脉瘤(根部19例、升主动脉88例)、三叶式主动脉瓣动脉瘤(根部25例、升主动脉90例)、A型夹层(升主动脉17例)及正常主动脉(根部12例、升主动脉28例)组织行双轴拉伸与分层测试。

主要发现

  • 在主动脉根部,MFS的能量损耗、低应变模量和分层强度与所有其他组均无统计学差异。
  • 在升主动脉,MFS分层强度低于正常升主动脉(31.9±8.5 mN/mm vs 57.1±17.0 mN/mm,P=0.0003)。
  • MFS升主动脉能量损耗高于正常(0.071±0.017 vs 0.049±0.011,P=0.04)。
  • MFS升主动脉低应变模量低于BAV(75.0±11.0 kPa vs 113.5±33.6 kPa,P=0.02)。

临床怎么用

  • 关注MFS升主动脉组织分层强度降低与能量损耗升高的生物力学改变,可能有助于理解其夹层风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: How Marfan syndrome (MFS) translates to alterations in ex vivo biomechanical properties of aortic tissue is not well defined. We aimed to characterize the biomechanical properties of the aortic root and ascending aorta in MFS and compare them to properties of normal, dissected, and non-MFS aneurysmal aortas. METHODS: Biaxial tensile and delamination testing were performed on aortic tissue from patients with MFS (root = 10, ascending = 6), aneurysms with bicuspid aortic valves (BAVs) (root = 19, ascending = 88), aneurysms with tricuspid aortic valves (root = 25, ascending = 90), type A dissections (ascending = 17), and normal aortas (root = 12, ascending = 28). Differences in energy loss, low strain modulus, and delamination strength were investigated between patient groups. RESULTS: In the aortic root, energy loss, low strain modulus, and delamination strength were not statistically different in MFS compared to all other groups. In the ascending aorta, delamination strength was lower in MFS than normal ascending aortas (31.9 ± 8.5 mN/mm vs 57.1 ± 17.0 mN/mm, P = 0.0003). The MFS group (0.071 ± 0.017) also had higher energy loss than normal (0.049 ± 0.011, P = 0.04), and lower low strain modulus (75.0 ± 11.0 kPa) than BAV (113.5 ± 33.6 kPa, P = 0.02). CONCLUSIONS: The root and ascending aorta in MFS proved to have distinct biomechanical characteristics compared to normal aortas and other risk groups.

来源:Eur J Cardiothorac Surg,查看原文。版权归原作者所有。