文献速递冠心病外科

不同灌注系统对孤立性体外循环冠脉搭桥全身炎症反应的前瞻性观察比较

Prospective observational study comparing systemic inflammatory responses across different perfusion systems during isolated on-pump Coronary Artery Bypass Grafting.
PubMed 文献 · Interdiscip Cardiovasc Thorac Surg · 2025-09-24

该单中心前瞻性预试验纳入66例主动脉阻断下孤立性体外循环CABG患者,比较MiECC、混合系统(HS)与常规体外循环(cCPB)的全身炎症与氧化应激标志物。MiECC与HS在术中及术后各时间点炎症标志物和氧化应激指标均低于cCPB,IL-6术后6小时分别为292、311与514 pg/mL,氧化应激指数为70、66与142。

要点

  • MiECC与HS较cCPB降低术中及术后炎症标志物与氧化应激指标。
  • cCPB患者红细胞输注比例为50%,MiECC为10%,HS为13.6%。
  • 三组肌钙蛋白、肌酐及乳酸值无显著差异。

核心结论

  • MiECC与HS减轻全身炎症反应的表现相似,且均优于cCPB。

研究设计与样本

  • 单中心前瞻性预试验观察研究,共纳入66例主动脉阻断下孤立性体外循环CABG患者。
  • 分组为MiECC(n=20)、HS(n=22)与cCPB(n=24)。
  • 在术前、术中及术后6、12、24小时检测炎症标志物与氧化状态。

主要发现

  • MiECC与HS组在术中及术后各时间点全身炎症生物标志物和氧化应激指标均低于cCPB组。
  • 术后6小时IL-6为MiECC 292 pg/mL、HS 311 pg/mL、cCPB 514 pg/mL。
  • 术后6小时氧化应激指数为MiECC 70、HS 66、cCPB 142。
  • 术后12小时HIF-1α在HS为3.8 ng/mL,高于MiECC的2.6 ng/mL。
  • 血红蛋白下降在MiECC组最轻,红细胞输注比例cCPB为50%、MiECC为10%、HS为13.6%。

关键数值与推荐

  • 初始分配至MiECC的2例患者因血流动力学不稳定术中转为cCPB。
  • 三组间肌钙蛋白、肌酐或乳酸值未见实质性差异。

临床怎么用

  • 在孤立性体外循环CABG中可考虑选用MiECC或HS以减轻炎症反应与氧化应激。
  • 选择MiECC时需警惕术中血流动力学不稳定导致转常规体外循环的可能。

局限性

  • 原文未报告局限性相关内容。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Minimal Invasive Extracorporeal Circulation (MiECC) and Hybrid System (HS) have been introduced to potentially reduce this inflammatory response compared to conventional Cardiopulmonary Bypass (cCPB). The hybrid system combines elements of conventional and minimized circuits, including a collapsible reservoir, integrated arterial filter, and hypobaric oxygenator, allowing rapid conversion and air embolism control.This study aims to provide a comparative analysis of biomarkers of systemic inflammatory response induced by MiECC, HS and cCPB systems in isolated CABG patients. METHODS: In this prospective pilot observational study a total of 66 patients who underwent isolated on-pump CABG performed under aortic cross-clamp enrolled. in this single-center, prospective pilot study. Systemic inflammatory markers (IL-1β, IL-6, IL-8, TNF-α, LE, HIF-1α) and oxidative status were measured at five intervals: preoperative (pre-pump), intraoperative (on-pump), and at 6, 12, and 24 hours postoperatively (post-pump). RESULTS: A total of 66 patients were enrolled: MiECC (n = 20), Hybrid System (HS, n = 22), and cCPB (n = 24). Notably, 2 patients initially assigned to MiECC required intraoperative conversion to cCPB due to haemodynamic instability. Both MiECC and HS groups consistently showed lower levels of systemic inflammatory biomarkers and oxidative stress indicators at all intraoperative and postoperative time points compared to cCPB. For instance, IL-6 levels at 6 hours post-op were 292 pg/mL in MiECC, 311 pg/mL in HS, and 514 pg/mL in cCPB; Oxidative Stress Index values at the same time point were 70 in MiECC, 66 in HS, and 142 in cCPB. Hemoglobin decline was least pronounced in the MiECC group, and red blood cell transfusion was required in 50% of cCPB patients, compared to 10% in MiECC and 13.6% in HS. HIF-1α levels were higher in HS than MiECC at 12 hours post-op (3.8 vs 2.6 ng/mL). No substantial differences were observed between groups in troponin, creatinine, or lactate values. CONCLUSIONS: MiECC and HS show a similar profile in alleviating systemic inflammation, with notable reductions in inflammatory biomarkers and key clinical oxidative outcomes compared with cCPB. These results underscore the potential of MiECC and HS to improve clinical recovery by minimizing the inflammatory effect in on-pump CABG procedures.

来源:Interdiscip Cardiovasc Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Kırali K, Aydın S, Güneş A, et al. Prospective observational study comparing systemic inflammatory responses across different perfusion systems during isolated on-pump Coronary Artery Bypass Grafting. Interdiscip Cardiovasc Thorac Surg. 2025. PMID: 40991336. doi:10.1093/icvts/ivaf221

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。