本研究纳入49例升主动脉手术修复患者,用定制分析插件从术前心电图门控CT(EGCT)测量主动脉壁弹性模量(E)与应变能(SE),并与切除标本离体加载试验对比。EGCT测得E与SE同离体试验呈强相关(r=0.733与r=0.773),Bland-Altman分析一致性良好,ICC示E信度良好至优秀(0.86)、SE中等(0.63)。
要点
- EGCT可无创评估主动脉壁弹性模量与应变能,与离体拉伸试验强相关。
- E的ICC为0.86,信度良好至优秀;SE的ICC为0.63,信度中等。
- 该方法有望用于主动脉灾难事件的风险分层,但预测准确性仍需进一步研究。
核心结论
- 基于EGCT的测量是無创评估主动脉力学特性的可行、可靠方法,未来或可改善主动脉灾难事件的风险分层。
研究设计与样本
- 对49例接受升主动脉手术修复的患者进行分析,术前用定制分析插件从EGCT获取在体测量,并对切除标本行离体加载试验。
- 用Spearman相关(r)、Bland-Altman分析与组内相关系数(ICC)评价两种方法的相关性与一致性。
主要发现
- EGCT测得的E与离体加载试验强相关(r=0.733),SE亦强相关(r=0.773)。
- Bland-Altman分析示一致性良好,E偏倚极小,SE呈负向比例偏倚。
- ICC示E信度良好至优秀(0.86),SE信度中等(0.63)。
关键数值与推荐
- 弹性模量E的ICC为0.86,应变能SE的ICC为0.63。
- E与离体试验的相关系数r=0.733,SE为r=0.773。
临床怎么用
- 可在术前EGCT扫描基础上用定制插件无创获取主动脉壁E与SE,辅助识别尺寸未达手术标准但力学风险高的患者。
局限性
- 作者指出需进一步研究以完善预测准确性。
- 摘要未报告样本量以外的更多局限信息。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Aortic aneurysm size is a key determinant for surgical intervention, but aortic catastrophes can occur before reaching the size criteria, indicating size alone is insufficient for risk assessment. Aortic mechanical properties could be another factor for predicting such catastrophes. However, its estimation in daily clinical settings remains impractical. This study aimed to validate a noninvasive electrocardiogram-gated computed tomography (EGCT)-based method for assessing aortic mechanical properties by comparing its measurements with ex vivo tensile testing of resected specimens. METHODS: We analysed 49 patients who underwent surgical repair of the ascending aorta. The mechanical properties of the aortic wall were assessed using two parameters: elastic modulus (E), representing stiffness and strain energy (SE), reflecting stored deformation energy. Ex vivo loading test was performed on resected specimens, while in vivo measurements were obtained from preoperative EGCT scans using a custom analysis plugin. Correlation and agreement between methods were evaluated using Spearman's correlation (r), Bland-Altman analysis and intraclass correlation coefficients (ICC). RESULTS: EGCT-based measurements of E and SE showed strong correlations with ex vivo loading test (r = 0.733 and r = 0.773, respectively). Bland-Altman analysis demonstrated good agreement, with minimal bias for E and a negative proportional bias for SE. ICC values indicated good-to-excellent reliability for E (0.86) and moderate reliability for SE (0.63). CONCLUSIONS: EGCT-based measurement is a feasible, reliable method for assessing aortic mechanical properties noninvasively. Although further studies are needed to refine predictive accuracy, this approach may enhance risk stratification for aortic catastrophes in future clinical practice.
引用
- Yokota J, Shirakawa T, Shimamura K, et al. In vivo aortic elasticity measurement using electrocardiogram-gated computed tomography: validation with ex vivo loading test. Interdiscip Cardiovasc Thorac Surg. 2025. PMID: 40828902. doi:10.1093/icvts/ivaf148
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。