罗马弓二尖瓣修复技术早期随访:巴黎经验
所有患者修复成功,无围术期或30天死亡,随访9±3个月仅2例(5%)复发二尖瓣反流(II级)。结论认为该技术简单可重复,早期超声结果满意,但样本量小且随访短,需更大规模前瞻性研究验证。
要点
- 40例二尖瓣修复均成功,无围术期及30天死亡。
- 随访9±3个月仅2例(5%)出现复发二尖瓣反流(II级)。
- 罗马弓技术基于单根连续缝线,操作简单且可重复性好。
核心结论
- 罗马弓技术基于单根连续缝线,作为二尖瓣修复方法技术简单且高度可重复,早期结果令人鼓舞。
- 早期超声心动图结果满意,但样本量有限且随访时间短,需更大规模前瞻性研究确认长期有效性。
研究设计与样本
- 原始技术经过修改以治疗任何二尖瓣脱垂。
主要发现
- 所有患者均成功完成二尖瓣修复。
- 平均主动脉阻断时间为74 ± 18分钟,体外循环时间为108 ± 23分钟。
- 修复技术包括瓣环成形术和罗马弓技术,常适应于治疗多个脱垂段。
- 无围术期死亡,也无30天死亡率记录。
- 1例患者(2.5%,95% CI:0.06%-13.2%)因感染性心内膜炎在术后8个月需要二尖瓣再干预。
临床怎么用
- 对于二尖瓣反流的患者,罗马弓技术可作为二尖瓣修复的一种简单且可重复的选择。
- 术后早期应进行超声心动图随访以监测复发二尖瓣反流和感染性心内膜炎等并发症。
局限性
- 样本量有限(40例)。
- 随访时间短(9 ± 3个月)。
- 需要更大规模的前瞻性研究来确认长期有效性和在现代二尖瓣修复策略中的潜在作用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Degenerative mitral valve disease presents peculiar surgical challenges in patients presenting with mitral regurgitation. We reviewed the early results of a novel set of techniques to validate the feasibility for patients who underwent mitral valve repair. METHODS: Between January 2024 and December 2024, 40 patients underwent mitral valve repair using artificial neochordal implantation following the principles of the Roman Arch technique. The original technique was modified in order to treat any mitral prolapse. We retrospectively reviewed the early post-operative clinical outcomes, and follow-up echocardiographic data. RESULTS: Successful mitral valve repair was performed in all patients. Mean aortic cross-clamp time was 74 ± 18 min while cardiopulmonary bypass time was 108 ± 23 min. Mitral valve repair techniques consisted of ring annuloplasty and the Roman Arch technique, oftenly adapted to treat multiple prolapsing segments. There were no peri-operative deaths nor there was any 30-day mortality recorded. One patient (2.5%, 95% CI: 0.06%-13.2%) needed mitral valve reintervention due to infective endocarditis occurred at 8 months after the index surgery. During the echocardiographic follow-up (9 ± 3 months) only 2 patients (5%, 95% CI: 0.6%-16.9%) presented a recurrent mitral regurgitation (grade II). CONCLUSIONS: In this initial experience, the Roman Arch technique, based on a single running suture, showed promising results as a technically simple and highly reproducible approach for mitral valve repair. Early echocardiographic outcomes were satisfactory. However, due to the limited sample size and short-term follow-up, larger and prospective studies are needed to confirm its long-term effectiveness and potential role within the spectrum of modern mitral valve repair strategies.
引用
- Zannis K, Messi P, Biondi R, et al. Early Follow-up of Roman Arch Mitral Valve Repair Technique: The Paris Experience. Eur J Cardiothorac Surg. 2025. PMID: 40758466. doi:10.1093/ejcts/ezaf262
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。