机器人辅助经导管主动脉瓣取出与主动脉瓣置换术
本文报告一例67岁女性患者,既往低危接受23 mm球囊扩张式TAVR,4年后出现严重人工主动脉瓣狭窄、射血分数降至35%、重度III型二尖瓣反流及症状性心衰。在获得知情同意后,经右侧腋窝工作切口行机器人辅助TAVR取出,并置换21 mm生物瓣主动脉瓣,同期行二尖瓣置换,总主动脉阻断时间195分钟,患者顺利出院。结论认为机器人TAVR取出和主动脉瓣置换可行,可能成为低至中危患者的未来选择。
要点
- 年轻患者TAVR后可能因瓣膜提前衰败需行外科取出。
- 机器人辅助经腋窝切口可行TAVR取出并同期双瓣置换。
- 该术式可能适用于低至中危外科风险患者。
核心结论
- 机器人TAVR取出和主动脉瓣置换可行,可能成为低至中危手术风险患者的未来选择。
研究设计与样本
- 病例报告:一例67岁女性,既往低危接受23 mm球囊扩张式TAVR,4年后因严重人工主动脉瓣狭窄等行机器人辅助TAVR取出及双瓣置换。
主要发现
- 患者术前射血分数降至35%,伴重度III型二尖瓣反流和症状性心衰。
- 手术经右侧腋窝工作切口完成机器人TAVR取出,并置换21 mm生物瓣主动脉瓣,同期行二尖瓣置换。
- 总主动脉阻断时间为195分钟,患者顺利出院。
关键数值与推荐
- 患者STS预测死亡风险为7.9%。
- TAVR瓣膜为23 mm球囊扩张式,植入时评为低危,4年后出现严重结构性瓣膜衰败。
临床怎么用
- 对于年轻、TAVR后瓣膜衰败且需双瓣置换的患者,可考虑机器人辅助非胸骨切开途径行TAVR取出和外科瓣膜置换。
局限性
- 本文为单例病例报告,结论的普遍适用性需进一步研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Transcatheter aortic valve replacement (TAVR) in younger patients may be complicated by premature structural valve degeneration. This report describes robotic TAVR explantation and aortic valve replacement. DESCRIPTION: A 67-year-old woman who underwent low-risk, 23-mm balloon-expandable TAVR 4 years previously presented with severe prosthetic aortic stenosis, a drop in ejection fraction to 35%, severe type III mitral regurgitation, and symptomatic heart failure. She had scoliosis and rheumatoid arthritis, and The Society of Thoracic Surgeons predicted risk of mortality was 7.9%. Given her younger age and need for double valve replacement, transcatheter options were deferred, and she was referred for intermediate- to high-risk nonsternotomy surgical consideration. EVALUATION: After obtaining informed consent, a right lateral transaxillary working incision facilitated robotic TAVR explantation, followed by 21-mm bioprosthetic aortic valve replacement with concomitant mitral valve replacement. The total cross-clamp time was 195 minutes. The patient recovered expectantly and was discharged home. CONCLUSIONS: Robotic TAVR explantation and aortic valve replacement are feasible and may represent a viable future option for patients of low to intermediate surgical risk.
引用
- Badhwar V, Darehzereshki A, Raikar GV, et al. Robotic-Assisted Transcatheter Aortic Valve Explantation and Aortic Valve Replacement. Ann Thorac Surg. 2025. PMID: 40750037. doi:10.1016/j.athoracsur.2025.07.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。