机器人肺解剖性切除中胸外科医生工效学与操作表现的客观评估
组1的RULA工效学评分显著更优(4.3 vs 4.7,P<.001),并伴随更高器械速度、更短任务完成时间和更短器械视野外时间,但路径长度无差异。结论认为视频运动追踪软件可有效客观评估机器人手术工效学与表现。
要点
- 视频运动追踪软件可无干扰地客观评估机器人手术工效学与操作表现。
- 机器人手术经验>100例者RULA工效学评分更优,操作速度更快、任务时间更短。
- RULA评分与各项操作表现参数之间无显著相关性。
核心结论
- 视频运动追踪软件是评估机器人手术工效学与操作表现的有效且无干扰的方法。
- 更好的工效学与更多机器人手术经验和更优的手术表现相关。
研究设计与样本
- 按机器人切除例数>100例(组1,专家)与<100例(组2,新手)分组比较。
- 使用RULA量表评估工效学风险,Kinovea-0.9.5系统测量操作表现与姿势。
主要发现
- 组1 RULA工效学评分显著优于组2(4.3 vs 4.7,P<.001)。
- 组1器械速度更高(2.8±0.8 vs 2.1±0.2 cm/s,P<.001)。
- 组1任务完成时间更短(388±278 vs 520±322 s,P=.001)。
- 组1器械视野外时间更短(P<.001)。
- 路径长度无差异(P=.8),RULA评分与操作表现参数无显著相关性。
临床怎么用
- 可考虑用视频运动追踪软件无干扰地客观评估机器人手术医生的工效学与操作表现。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Motion tracking tools have been used in the analysis of surgeons' technical expertise and posture in simulated endoscopic surgery. But its use in humans in real-life robotic surgery is limited. We analysed the effect of surgeons' ergonomics and posture on skill metrics for vascular dissection during anatomical pulmonary resection. METHODS: In this observational study of vascular dissection/division during segmentectomy or lobectomy, we analysed the inter-group differences of those with more than (group 1) and less than (group 2) 100 robotic resections. The rapid upper limb assessment (RULA) scale was used to estimate ergonomic risk. Operative performance and posture for RULA were measured using the Kinovea-0.9.5 system. Path length of moving instruments, instrument speed, time for task completion, and duration of instruments out of vision were calculated to objectively assess operator performance. RESULTS: Group 1 (expert) comprised 2 males and 1 female, aged 42-61 years. Group 2 (novice) comprised 4 males, aged 31-52 years. Sixty-seven patients underwent robotic anatomical resection using the da Vinci Xi robotic platform, with 180 pulmonary vessels isolations/divisions (Group 1 = 95 vs Group 2 = 85). Group 1 had significantly better RULA ergonomic scores (4.3 vs 4.7, P < .001) which was associated with higher speed (2.8 ± 0.8 vs 2.1 ± 0.2 cm/s, P < .001), shorter task completion time (388 ± 278 vs 520 ± 322 s, P = .001), and shorter duration of instruments out of vision (P < .001). There was no difference in path length (P = .8) and no significant correlation between RULA score and different parameters that assessed surgical performance. CONCLUSIONS: Video motion tracking software is an effective and unobtrusive method to evaluate surgical ergonomics and performance in robotic surgery. Better ergonomics were associated with increased surgical experience and improved surgical performance.
引用
- Elkhouly AG, Santhirakumaran G, Shanahan B, et al. Objective Assessment of Ergonomics and Performance of Thoracic Surgeons During Real-Life Anatomical Robotic Pulmonary Resections. Interdiscip Cardiovasc Thorac Surg. 2025. PMID: 40728938. doi:10.1093/icvts/ivaf180