不同钳夹技术对人肺动脉内膜损伤的组织学评估
DLT与VLT均未出现MZS 3-5级损伤,DeBakey第四齿损伤显著高于DLT;DLT是胸腔镜钳夹可行且安全的技术。
要点
- DLT在全部病例中达到≥30 mmHg的爆破压力,且无MZS 3-5级内膜损伤。
- DeBakey第四齿的改良Zhang评分显著高于DLT(P=0.029)。
- DLT、VLT和gold clip适用于外周肺动脉钳夹。
核心结论
- DLT是胸腔镜钳夹可行且安全的技术。
- DLT、VLT和gold clip适用于钳夹外周肺动脉。
- 使用DeBakey血管钳时,应根据血管直径谨慎选择齿槽。
研究设计与样本
- 前瞻性分析2个中心2021年4月至2025年3月接受解剖性肺切除术的患者。
- 评估DLT、DeBakey血管钳(第三和第四齿)、Fogarty血管钳(第二齿)、血管夹(gold和silver)及VLT。
- 测量爆破压力,并用改良Zhang评分(MZS;0-5)评估内膜损伤。
主要发现
- DeBakey第三齿的爆破压力显著高于DLT(P=0.022)。
- DLT与VLT之间爆破压力无显著差异(P=0.453)。
- 所有DLT病例均达到爆破压力≥30 mmHg。
- DLT和VLT钳夹的样本均未出现MZS 3-5。
- DeBakey第四齿的MZS值显著高于DLT(P=0.029)。
关键数值与推荐
- MZS评分范围0-5分。
- 爆破压力≥30 mmHg在全部DLT病例中达到。
- DeBakey第三齿爆破压力显著高于DLT(P=0.022)。
- DeBakey第四齿MZS显著高于DLT(P=0.029)。
临床怎么用
- 胸腔镜手术中可优先考虑DLT钳夹肺动脉。
- 外周肺动脉钳夹可选用DLT、VLT或gold clip。
- 使用DeBakey血管钳时需根据血管直径选择合适齿槽。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: We evaluated intimal damage at the histological level resulting from various clamp techniques in human pulmonary artery (PA) specimens obtained after lobectomy. METHODS: We prospectively analysed patients who underwent anatomical lung resection at 2 centres between April 2021 and March 2025. The double-loop technique (DLT), DeBakey vascular clamp (third and fourth notches), Fogarty vascular clamp (second notch), endovascular clips (gold and silver), and vessel loop technique (VLT) were evaluated. PA specimens with an external diameter ≥10 mm were included. We measured the burst pressure and evaluated the intimal damage in the human PA by using the modified Zhang's score (MZS; 0-5). RESULTS: Thirty-six patients were enrolled, and 70 PA samples were obtained. DeBakey vascular clamp at the third notch (DeBakey 3rd) exerted a significantly higher burst pressure than did DLT (P = 0.022). No significant difference was found between DLT and VLT (P = 0.453). A burst pressure ≥30 mmHg was achieved in all DLT cases. None of the samples clamped with DLT and VLT exhibited MZS 3-5. The rate of MZS ≥2 with DeBakey 3rd, Fogarty vascular clamp at the second notch (Fogarty 2nd), gold and silver clips, and VLT was statistically comparable to that for DLT, whereas DeBakey vascular clamp at the fourth notch (DeBakey 4th) resulted in significantly higher MZS values than did DLT (P = 0.029). CONCLUSIONS: The DLT is a feasible and safe for thoracoscopic clamping. Additionally, DLT, VLT, and gold clip are appropriate for clamping the peripheral PA. For DeBakey vascular clamp, notch selection should be carefully tailored to the vessel diameter.
引用
- Chiba Y, Miyajima M, Takahashi Y, et al. Histological Evaluation of Human Pulmonary Artery Intimal Damage Caused by Various Clamp Techniques. Eur J Cardiothorac Surg. 2025. PMID: 40658467. doi:10.1093/ejcts/ezaf232
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。