全弓置换联合杂交冷冻象鼻与分支支架吻合冷冻象鼻修复的对比
本研究比较了中度低温(25-28°C)下分支支架吻合冷冻象鼻修复(B-SAFER)与轻度低温(>32°C)下全弓杂交冷冻象鼻(HA-FET)重建的短期结果。两种技术均安全有效。
要点
- HA-FET组循环停止时间显著短于B-SAFER组(9 vs 40分钟)。
- 两组神经功能障碍和院内死亡率无显著差异。
- 两种技术短期结果均安全良好,需更大样本和长期随访。
核心结论
- 轻度低温全弓杂交FET修复与中低温B-SAFER技术均提供安全且良好的短期结果。
主要发现
- HA-FET组循环停止时间显著更短(9 vs 40分钟,P < .001),体外循环和交叉钳夹时间相似。
- HA-FET组伴随主要心脏手术比例更高(13/25,52% vs 10/36,27%,P = .066)。
- 神经功能障碍(4% vs 5.4%,P = 1)和院内死亡率(4% vs 8.1%,P = .64)相似。
- 无截瘫发生,需透析的肾衰竭在HA-FET组为12%,B-SAFER组为8.1%(P = .68)。
临床怎么用
- 两种技术均可用于全弓置换,HA-FET可显著缩短循环停止时间。
局限性
- 样本量较小,需更大队列和长期随访研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: This study aims to evaluate the short-term outcomes of total arch replacement using 2 techniques: the branched stented anastomosis frozen elephant trunk repair (B-SAFER) under moderate hypothermia (25-28 °C), and a simplified total arch and hybrid arch frozen elephant trunk (HA-FET) reconstruction using the Thoraflex stent graft under mild hypothermia (>32 °C). METHODS: Sixty-one patients underwent total arch replacement between June 2020 and March 2024. 25 received HA-FET, and 36 received B-SAFER. Central cannulation and cerebral debranching of the innominate and left common carotid arteries were performed before circulatory arrest in both groups. Axillary cannulation led to debranching after circulatory arrest. In the HA-FET group, snares were placed circumferentially in zone 1 and zone 2 prior to circulatory arrest and deployment of FET graft; in B-SAFER, antegrade thoracic stent graft was deployed in zone 2 with left subclavian fenestration and stenting. RESULTS: Mean age 57.4 ± 13.1 years, with 74% male. Acute type A was the pathology in 60% of HA-FET and 58% of B-SAFER patients. HA-FET had significantly shorter circulatory arrest times (9 vs 40 minutes, P < .001) but similar cardiopulmonary bypass and cross-clamp times. The rate of concomitant major cardiac procedure was higher in HA-FET group (13/25, 52% vs 10/36, 27%, P = .066). Neurologic dysfunction (4% vs 5.4%, P = 1) and in-hospital mortality (4% vs 8.1%, P = .64) were similar. No paraplegia occurred, and renal failure requiring dialysis occurred in 12% of HA-FET and 8.1% of B-SAFER patients (P = .68). CONCLUSIONS: Both mild hypothermic total arch with hybrid FET repair and hypothermic total arch replacement utilizing B-SAFER technique provide safe and favourable short-term outcomes. Further studies with larger cohorts and long-term follow-up are required.
引用
- Shah A, Leibowitz J, Lu J, et al. Total Arch With Hybrid Frozen Elephant Trunk Versus Branched Stented Anastomosis Frozen Elephant Trunk Repair. Interdiscip Cardiovasc Thorac Surg. 2025. PMID: 40644331. doi:10.1093/icvts/ivaf164
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。