新型混合假体修复急性DeBakey I型夹层后脑灌注不良的改善:PERSEVERE研究早期结果
PERSEVERE研究在北美26个中心纳入93例急性DeBakey I型夹层伴灌注不良患者,其中30例(32.3%)存在脑灌注不良,评估半弓修复联合AMDS混合假体后的神经结局。临床脑灌注不良19例中18例存活,11例(61%)症状完全缓解,5例(28%)无加重,2例(11%)出现新发致残性卒中;影像学脑灌注不良患者无名动脉和左颈总动脉真腔/总动脉直径比显著改善。
要点
- AMDS混合假体半弓修复后多数脑灌注不良患者神经症状缓解或稳定。
- 临床脑灌注不良者术后新发致残性卒中比例为11%。
- 影像学脑灌注不良者无名动脉和左颈总动脉真腔比例显著改善。
核心结论
- 急性DeBakey I型夹层伴脑灌注不良患者,使用AMDS行半弓修复后多数神经症状缓解或稳定,影像学灌注不良指标改善。
研究设计与样本
- PERSEVERE研究在北美26个中心纳入93例急性DeBakey I型夹层伴灌注不良患者,其中30例(32.3%)存在脑灌注不良,评估半弓修复联合AMDS后的脑灌注不良缓解情况。
主要发现
- 临床脑灌注不良19例(63.3%),影像学脑灌注不良23例(76.7%)。
- 临床脑灌注不良患者中18例围术期存活,11例(61%)症状完全缓解,5例(28%)无加重,2例(11%)出现新发致残性卒中。
- 影像学脑灌注不良患者随访时无名动脉真腔/总动脉直径比从30.9%改善至64.4%(P=0.002),左颈总动脉从33.8%改善至60.6%(P=0.005)。
关键数值与推荐
- 临床脑灌注不良诊断19例(63.3%),影像学诊断23例(76.7%)。
- 临床脑灌注不良存活者中症状完全缓解61%,无加重28%,新发致残性卒中11%。
- 无名动脉真腔/总动脉直径比从30.9%升至64.4%(P=0.002),左颈总动脉从33.8%升至60.6%(P=0.005)。
临床怎么用
- 对于急性DeBakey I型夹层伴脑灌注不良患者,可考虑使用AMDS混合假体行半弓修复以改善神经结局和主动脉重塑。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Patients undergoing hemiarch repair for acute DeBakey type I dissection (ADTI) are high risk for postoperative stroke, especially if cerebral malperfusion is present preoperatively. We sought to evaluate whether the AMDS Hybrid Prosthesis (AMDS), a bare metal stent designed to promote positive aortic remodelling and prevent distal anastomotic new entry tears, may improve neurological outcomes of patients with ADTI presenting with cerebral malperfusion. METHODS: PERSEVERE enrolled patients presenting with ADTI and malperfusion at 26 sites in North America. Among 93 enrolled patients, 30 (32.3%) presented with cerebral malperfusion. We evaluated for resolution of clinical and/or radiological cerebral malperfusion after hemiarch repair with AMDS. RESULTS: Cerebral malperfusion was diagnosed clinically in 19 (63.3%) patients and radiographically in 23 (76.7%) patients. Among the patients with clinical cerebral malperfusion, 18 survived the perioperative period; of these, 11 (61%) experienced complete resolution of preoperative symptoms, 5 (28%) had no worsening of preoperative symptoms, and 2 (11%) had a new disabling stroke postoperatively. At follow-up, the mean true lumen to total arterial diameter ratio (measured by computed tomography angiography) improved from 30.9% to 64.4% (P = 0.002) in the innominate artery and 33.8% to 60.6% (P = 0.005) in the left common carotid artery from preoperative baseline in patients with radiographic cerebral malperfusion. CONCLUSIONS: Among patients presenting with ADTI and cerebral malperfusion, the majority had resolution or stability of neurological symptoms after hemiarch repair using the AMDS. Radiographic indicators of malperfusion also improved. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/study/NCT05174767.
引用
- Brinkman W, Squiers JJ, Jassar A, et al. Cerebral malperfusion resolution after repair of acute DeBakey type I dissection with a novel hybrid prosthesis: early results of the PERSEVERE Study†. Eur J Cardiothorac Surg. 2025. PMID: 40586922. doi:10.1093/ejcts/ezaf199
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。