文献速递瓣膜外科

ELASTA-clip联合经心尖二尖瓣置换治疗TEER失败:有前景的替代方案

Electrosurgical Laceration and Stabilization of Clip Followed by Transapical Mitral Valve Replacement after Failed Transcatheter Edge-to-Edge Mitral Valve Repair: A Promising Alternative to Surgery.
PubMed 文献 · Interdiscip Cardiovasc Thorac Surg · 2025-01-01

该回顾性研究分析经导管缘对缘二尖瓣修复失败后行ELASTA-clip联合经心尖二尖瓣置换或传统开放手术的围术期结局。ELASTA组5例,开放手术组31例。ELASTA组手术成功率100%,无院内死亡;开放手术组成功率96%,死亡率6.5%。随访不良事件分别为20%和54.8%。

要点

  • TEER失败后外科干预并发症风险高
  • ELASTA-clip联合经心尖置换微创且安全
  • 需前瞻性长随访研究进一步验证

核心结论

  • TEER失败后外科干预并发症风险高,ELASTA-clip联合经心尖二尖瓣置换提供微创安全替代方案。

研究设计与样本

  • 回顾性分析连续TEER失败后行ELASTA-clip联合经心尖二尖瓣置换或传统开放二尖瓣手术的患者。
  • ELASTA组5例,开放手术组31例;中位随访分别为2年(IQR 1.2-2.1)和1.4年(IQR 0.3-3.7)。

主要发现

  • ELASTA组手术成功率100%,开放手术组96%。
  • ELASTA组无院内死亡,开放手术组死亡率为6.5%(n=2)。
  • 随访期间不良事件发生率ELASTA组20%(n=1),开放手术组54.8%(n=17)。

临床怎么用

  • 对于TEER失败后需干预的患者,可考虑ELASTA-clip联合经心尖二尖瓣置换作为传统手术的微创替代。

局限性

  • 回顾性设计,样本量小(ELASTA组5例),随访时间有限,需前瞻性长随访研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The study analyses perioperative outcomes in patients who underwent transcatheter electrosurgical laceration and stabilization of the clip (ELASTA-clip), followed by transapical mitral valve replacement or conventional mitral valve surgery (MVS) after failed transcatheter edge-to-edge mitral valve repair. METHODS: Consecutive patients who experienced failure of a transcatheter edge-to-edge mitral valve repair and subsequently underwent either the ELASTA-clip procedure followed by transapical mitral valve replacement or conventional open MVS were retrospectively analysed. Perioperative and mid-term outcomes including mortality, stroke, bleeding, pacemaker implantation, and the need for mechanical circulatory support were assessed descriptively. RESULTS: A total of 5 patients were enrolled in the ELASTA group and 31 in the open surgery group, with median follow-up periods of 2 years [IQR: 1.2-2.1] and 1.4 years [IQR: 0.3-3.7], respectively. Procedural success was achieved in all ELASTA cases (100%) compared to 96% in the open surgery group. No in-hospital deaths occurred in the ELASTA group, whereas the surgical group had a mortality rate of 6.5% (n = 2). During follow-up, adverse events occurred in 20% (n = 1) of ELASTA patients and 54.8% (n = 17) of those who underwent surgery. CONCLUSIONS: Surgical intervention in patients with failed edge-to-edge mitral valve repair carries a high risk of complications. The ELASTA-clip technique, combined with transapical mitral valve replacement, offers a minimally invasive and safe alternative to conventional surgery, highlighting the need for further prospective studies with longer-term follow-up.

来源:Interdiscip Cardiovasc Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Pregaldini F, Çelik M, Nucera M, et al. Electrosurgical Laceration and Stabilization of Clip Followed by Transapical Mitral Valve Replacement after Failed Transcatheter Edge-to-Edge Mitral Valve Repair: A Promising Alternative to Surgery. Interdiscip Cardiovasc Thorac Surg. 2025. PMID: 40742024. doi:10.1093/icvts/ivaf183

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。