文献速递瓣膜外科

烟囱Commando术在再次双瓣置换术中的早期结局:回顾性队列研究

Early outcomes of chimney commando procedure in redo double valve replacement: A retrospective cohort study.
PubMed 文献 · J Thorac Cardiovasc Surg · 2025-07-18

该回顾性队列研究纳入194例再次双瓣置换术患者,比较烟囱Commando(CC)联合双瓣置换(DVR)与单纯DVR的早期结局。CC+DVR组瓣环尺寸增加、有效瓣口面积更大、主动脉瓣最大流速更低,30天死亡率与术后并发症无显著差异。结论认为CC术或为双小瓣环再次DVR的安全有效方案,但长期结局需进一步随访。

要点

  • CC术可增大主动脉瓣与二尖瓣标称尺寸,改善瓣口面积和血流动力学。
  • CC+DVR组30天全因死亡率与单纯DVR组相似,术后并发症无显著差异。
  • 瓣环扩大可能有利于未来经导管瓣膜植入,但长期结局仍需随访。

核心结论

  • CC术或为双小瓣环再次DVR的安全有效方案,提供良好血流动力学和有利早期结局。
  • 长期结局仍需进一步随访,瓣环扩大可能有利于未来经导管瓣膜植入。

主要发现

  • CC+DVR组主动脉瓣标称尺寸中位增加4(IQR 2.0-6.0),二尖瓣中位增加2(IQR 2-4),DVR组无变化。
  • CC+DVR组有效瓣口面积(2.0±0.1 vs 1.8±0.1 cm2;P<.001)和有效瓣口面积指数(1.3±0.1 vs 1.2±0.1 cm2/m2;P<.001)显著更大。
  • CC+DVR组主动脉瓣最大流速更低(1.9±0.3 vs 2.3±0.4 m/second;P<.001),血流动力学获益持续至随访。
  • 术后并发症无显著差异(P>.05);30天全因死亡率相似(2.8% vs 1.4%;P=1.000)经调整后。
  • CC+DVR组1例患者术后2个月死于脑梗死。

临床怎么用

  • 对于双小瓣环再次双瓣置换患者,可考虑采用烟囱Commando术以增大瓣环尺寸并改善血流动力学。
  • CC术早期安全性与单纯DVR相当,但需注意远期结局和个体化评估。

局限性

  • 回顾性队列研究设计,可能存在选择偏倚。
  • 随访时间较短(中位14个月),长期结局未明。
  • 样本量有限,部分结果需更大规模研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess the early outcomes of the chimney commando (CC) procedure in patients who underwent redo double valve replacement (DVR) with and without CC. METHODS: A retrospective cohort study of 194 patients undergoing redo DVR at Wuhan Asia Heart Hospital from December 2019 to December 2024. One hundred one patients were in the CC + DVR group and 93 were in an isolated DVR group. A total of 188 patients completed follow-up, The median follow-up time was 14 months (range, 6-36 months). The primary outcome was 30-day mortality; secondary outcomes were postoperative complications and hemodynamics. RESULTS: After surgery, the median labeled size increase was 4 (interquartile range, 2.0-6.0) for aortic and 2 (interquartile range, 2-4) for mitral valves in the CC + DVR group, with no change in the DVR group. The effective orifice area (2.0 ± 0.1 vs 1.8 ± 0.1 cm2; P < .001) and effective orifice area index (1.3 ± 0.1 vs 1.2 ± 0.1 cm2/m2; P < .001) were significantly larger in the CC + DVR group. The aortic valve maximum velocity in the CC + DVR group (1.9 ± 0.3 vs 2.3 ± 0.4 m/second; P < .001) were lower than in the DVR group, with these hemodynamic benefits sustained during follow-up. Postoperative complications showed no significant differences (P > .05). Thirty-day all-cause mortality was similar (2.8% vs 1.4%; P = 1.000) after adjustment. One patient from the CC + DVR group died from a cerebral infarction 2 months after surgery. CONCLUSIONS: The CC procedure maybe a safe and effective solution for redo DVR with double small annuli, offering good hemodynamics and favorable early outcomes. Long-term outcomes still require further follow-up. Annular enlargement may also facilitate future transcatheter valve implantation.

来源:J Thorac Cardiovasc Surg,查看原文。版权归原作者所有。

引用

  1. Liu H, Hua Z, He B, et al. Early outcomes of chimney commando procedure in redo double valve replacement: A retrospective cohort study. J Thorac Cardiovasc Surg. 2025. PMID: 40684851. doi:10.1016/j.jtcvs.2025.07.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。