文献速递冠心病外科

Meta分析:有创与CT血管造影评估冠脉搭桥移植血管通畅性的比较

Meta-Analysis of Coronary Bypass Graft Patency Assessment With Invasive vs Computed Tomographic Angiography.
PubMed 文献 · Ann Thorac Surg · 2025-07-01

该Meta分析纳入50项研究、3449例CABG术后患者,比较CT冠状动脉造影与有创冠状动脉造影检测移植血管闭塞的诊断性能。CT冠状动脉造影汇总敏感度0.96、特异度0.97、阳性预测值0.94、阴性预测值0.98、总体诊断准确率0.97,且不受移植血管类型和构型影响。

要点

  • CT冠状动脉造影检测CABG移植血管闭塞的汇总敏感度0.96、特异度0.97。
  • 诊断性能不受移植血管类型和构型影响,可用于各类CABG移植血管成像。
  • 研究年份、样本量、β受体阻滞剂使用、扫描层数及术后时间与敏感度相关。

核心结论

  • CT冠状动脉造影检测CABG移植血管闭塞具有高敏感度和特异度,且独立于移植血管类型和构型,可用于各类CABG移植血管成像。

研究设计与样本

  • Meta分析检索MEDLINE、Embase和Cochrane数据库,纳入比较CT冠状动脉造影与有创冠状动脉造影检测CABG术后移植血管闭塞的研究。
  • 共纳入50项研究、3449例患者(25%为女性),汇总分析7506条移植血管。
  • 采用随机效应模型计算汇总估计值,以I2衡量异质性,并用Meta回归探索关键修饰因素。

主要发现

  • CT冠状动脉造影检测移植血管闭塞的汇总敏感度为0.96(I2=48%),特异度为0.97(I2=46%)。
  • 汇总阳性预测值为0.94(I2=62%),阴性预测值为0.98(I2=41%),总体诊断准确率为0.97(I2=58%)。
  • 7506条移植血管的汇总闭塞发生率为0.08/移植血管年(95%CI 0.06-0.10,随机效应模型)和0.07/移植血管年(95%CI 0.07-0.08,固定效应模型)。
  • Meta回归显示研究年份、样本量、β受体阻滞剂使用、扫描层数及术后时间与CT冠状动脉造影敏感度显著相关,而移植血管类型和构型与之无显著相关。

临床怎么用

  • CT冠状动脉造影可作为无创替代方法用于CABG术后移植血管通畅性评估,适用于各类移植血管。
  • 解读CT冠状动脉造影结果时需考虑研究年份、扫描层数、术后时间等因素对敏感度的潜在影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Computed tomographic (CT) coronary angiography has emerged as a noninvasive alternative for evaluating graft patency after coronary artery bypass grafting (CABG), but there is ongoing debate regarding its diagnostic performance compared with invasive coronary angiography, particularly for arterial and composite grafts. METHODS: MEDLINE (Medical Literature Analysis and Retrieval System Online), Embase, and Cochrane databases were searched to identify studies comparing CT coronary angiography with invasive coronary angiography for detection of graft occlusion in patients who had undergone CABG. Outcomes included sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy. Meta-regression explored key modifiers. Pooled estimates were calculated using random-effects models, with heterogeneity measured by I2. RESULTS: Fifty studies met inclusion criteria, including 3449 patients (25% women). CT coronary angiography sensitivity for graft occlusion was 0.96 (I2 = 48%), specificity was 0.97 (I2 = 46%), positive predictive value was 0.94 (I2 = 62%), negative predictive value was 0.98 (I2 = 41%), and overall diagnostic accuracy was 0.97 (I2 = 58%). The pooled incidence rate of graft occlusion across 7506 included grafts was 0.08 per graft-year (95% CI, 0.06-0.10) using a random-effects model and 0.07 per graft-year (95% CI, 0.07-0.08) using a fixed-effects model. At meta-regression, study year, sample size, β-blocker use, number of slices, and time since surgery, but not type and configuration of CABG grafts, were significantly associated with CT coronary angiography sensitivity. CONCLUSIONS: CT coronary angiography detects CABG graft occlusion with a high degree of sensitivity and specificity independently of graft type and configuration and can be used for imaging of every type of CABG graft.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Mantaj P, Hirofuji A, Dell'Aquila M, et al. Meta-Analysis of Coronary Bypass Graft Patency Assessment With Invasive vs Computed Tomographic Angiography. Ann Thorac Surg. 2025. PMID: 40609668. doi:10.1016/j.athoracsur.2025.06.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。