文献速递肺外科

CT用于亚肺叶切除标本术中手术切缘评估

Intraoperative Surgical Margin Assessment of Sublobar Lung Resection Specimens Using Computed Tomography.
PubMed 文献 · Ann Thorac Surg · 2025-06-23

本研究纳入52例亚肺叶切除标本,比较CT与病理测量的手术切缘长度。Bland-Altman分析平均差1.2 mm,95%一致性界限-7.2至9.6 mm。亚实性肿瘤和胸膜深度是影响测量差异的独立因素。

要点

  • CT测量手术切缘可行,有望辅助术中切缘评估
  • 亚实性肿瘤和胸膜深度影响CT与病理切缘的差异

核心结论

  • CT测量手术切缘可行,有潜力辅助术中切缘评估,但亚实性肿瘤差异可能更大。

研究设计与样本

  • 前瞻性纳入计划行肺段切除或楔形切除的患者,切除后肺样本复张行CT扫描,共分析52例标本。

主要发现

  • Bland-Altman分析显示CT与病理切缘的平均差异为1.2 mm,95%一致性界限为-7.2至9.6 mm。
  • 52例标本中实性肿瘤34例(65.4%),亚实性肿瘤18例(34.6%)。

临床怎么用

  • 术中可用CT测量切缘辅助评估,但需注意CT值较病理偏小约10.6%。
  • 对亚实性肿瘤使用CT评估切缘时,应预期更大的测量差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: While early lung cancers are increasingly managed with sublobar resection, inadequate surgical margin (SM) is still a major concern, increasing the risk of locoregional recurrence. In this study, we evaluated the feasibility of using computed tomography (CT) as an intraoperative SM guidance tool by comparing with histopathologic SM measurement. METHODS: Patients scheduled for segmentectomy or wedge resection were enrolled. Immediately after resection, lung samples were reinflated and CT images were acquired. SM length, defined as the distance between the tumor and staple line, was measured by both CT and pathology. CT-derived SM length was compared with pathology-derived SM length using Bland-Altman analysis. Factors affecting differences between the 2 measurements were assessed using multiple linear regression analysis. RESULTS: A total of 52 resected specimens were analyzed. There were 34 solid (65.4%) and 18 subsolid tumors (34.6%). The mean SM length by CT and pathology was 11.3 mm and 10.1 mm, respectively. There was overall a 10.6% reduction from CT to pathology (P = .033). In Brand-Altman analysis, the mean difference between SM on CT and pathology was 1.2 mm, with the 95% limits of agreement from -7.2 to 9.6 mm. The multiple linear regression analysis revealed that subsolid tumors (P = .047) and depth from pleura (P < .01) were independent factors affecting SM discrepancy. CONCLUSIONS: SM measurement by CT is feasible and has the potential to aid in the evaluation of SM intraoperatively. However, surgeons must anticipate the potentially greater discordance when using this technique for subsolid tumors.

来源:Ann Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Kitazawa S, Bernards N, Sata Y, et al. Intraoperative Surgical Margin Assessment of Sublobar Lung Resection Specimens Using Computed Tomography. Ann Thorac Surg. 2025. PMID: 40562272. doi:10.1016/j.athoracsur.2025.06.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。