无缝合II型杂交主动脉弓修复术治疗急性A型主动脉夹层的手术技术
该研究描述了采用血管环连接器、造影辅助无缝合套叠吻合技术及胸主动脉腔内修复的无缝合II型杂交主动脉弓修复术,纳入2022年1月至2023年4月共19例急性A型主动脉夹层患者。中位手术时间397分钟,体外循环时间184分钟,院内死亡2例(10.5%)。随访中重建弓部血管均通畅,弓部及胸主动脉内假体水平主动脉重塑阳性率分别为100%和94.2%。
要点
- 无缝合II型杂交弓修复术治疗急性A型主动脉夹层可行,中期随访结果良好
- 院内死亡2例(10.5%),中位随访553天,重建弓部血管均通畅
- 弓部及胸主动脉内假体水平主动脉重塑阳性率分别为100%和94.2%
核心结论
- 无缝合II型杂交主动脉弓修复术可行,手术完全成功且中期随访术后结果良好,但需长期监测评估耐久性和潜在并发症。
研究设计与样本
- 回顾性收集2022年1月至2023年4月共19例接受无缝合II型杂交弓修复术的急性A型主动脉夹层患者,描述手术技术并分析术前人口学、手术细节、术后结局和随访结果。
主要发现
- 19例患者中位年龄62岁(IQR:10.5),男性占73.7%。
- 中位手术时间397分钟(IQR:111.5),体外循环时间184分钟(IQR:52.5);完全无缝合II型杂交弓修复术进一步缩短上述时间。
- 院内死亡2例(10.5%)。
- 弓部水平主动脉重塑阳性率为100%,胸主动脉内假体水平为94.2%。
临床怎么用
- 对于急性A型主动脉夹层,可考虑采用无缝合II型杂交弓修复术,该术式可行且中期随访结果良好。
- 术后需规律影像学随访评估弓部血管通畅性和主动脉重塑情况。
- 需长期监测以评估该术式的耐久性和潜在并发症。
局限性
- 原文未明确报告研究局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Hybrid arch repair improved surgical outcomes in aneurysmal disease. Sutureless anastomosis using an intraluminal ringed graft and stent graft bridging has been reported. We incorporate the vascular ring connector, angiography-assisted sutureless telescoping anastomosis technique, and thoracic endovascular aortic repair, rendering the hybrid arch repair for acute type A aortic dissection sutureless. Herein, we presented our sutureless procedure for acute type A aortic dissection. METHODS: Between January 2022 and April 2023, 19 patients who underwent sutureless type II hybrid arch repair were enrolled. The surgical procedures were described. The preoperative demographics, operative details, postoperative outcomes and follow-up results were retrospectively collected. RESULTS: Nineteen patients with a median age of 62 (interquartile range [IQR]: 10.5) and male dominant in 73.7% were recorded. The sutureless type II hybrid arch repair was performed in a median operative time of 397 min (IQR: 111.5), with a cardiopulmonary bypass time of 184 min (IQR: 52.5). The fully sutureless type II hybrid arch repair further reduced the abovementioned times. In-hospital death was two in 10.5%. Seventeen discharged patients had regular follow-ups in a median of 553 days (IQR: 129). The serial computed tomography scan revealed all reconstructed arch vessels were patent, and positive aortic remodelling was observed at the arch and thoracic endoprosthesis levels at 100% and 94.2%, respectively. CONCLUSIONS: Sutureless type II hybrid arch repair is feasible, demonstrating complete procedural success and favourable postoperative outcomes in mid-term follow-up. Long-term monitoring is necessary to assess this procedure's durability and potential complications.
引用
- Chang JC, Huang SM, Hii IH, et al. Operative technique: sutureless type II hybrid arch repair for acute type A aortic dissection. Interdiscip Cardiovasc Thorac Surg. 2025. PMID: 40198256. doi:10.1093/icvts/ivaf081
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。