文献速递瓣膜外科主动脉外科

心电图门控心脏CT辅助评估主动脉瓣可修复性:一项初步研究

Use of complementary electrocardiogram-gated cardiac computed tomography in the assessment of aortic valve repairability: a pilot study†.
PubMed 文献 · Interdiscip Cardiovasc Thorac Surg · 2025-01-01

该初步研究纳入24例接受非急诊主动脉瓣修复术的患者,比较超声心动图与心电图门控心脏CT测量主动脉瓣几何高度、瓣环及交界方向的信度。结果显示CT在二叶式主动脉瓣交界方向(ICC=0.98)与融合瓣几何高度(ICC=0.91)信度极佳,在三叶式主动脉瓣左冠瓣几何高度(ICC=0.76)与瓣环直径(ICC=0.8)信度良好。提示心电图门控CT可作为超声的补充用于术前评估主动脉瓣可修复性。

要点

  • 心电图门控CT与超声在主动脉瓣形态评估及交界方向上有极佳一致性。
  • 二叶式主动脉瓣中融合瓣几何高度CT信度极佳(ICC=0.91)。
  • 三叶式主动脉瓣中瓣环直径与左冠瓣几何高度CT信度良好。

核心结论

  • 心电图门控心脏CT可补充超声心动图用于主动脉瓣修复术前评估,在形态学评估和交界方向上显示极佳一致性。
  • CT对二叶式主动脉瓣的几何高度以及三叶式主动脉瓣的瓣环直径和左冠瓣几何高度尤其可靠。

研究设计与样本

  • 采用组内相关系数比较超声心动图与心电图门控扫描测量的几何高度、主动脉瓣环和交界方向的评定者间信度。

主要发现

  • 全部24例患者均为男性,中位年龄47.5岁(41.9-59.3)。
  • 87.5%的患者存在重度主动脉瓣反流,62.5%合并主动脉病变。
  • 58.3%的患者为纽约心脏协会心功能I级,其余41.7%为II级。
  • 62.5%的患者主动脉瓣为二叶式。
  • 心电图门控扫描在二叶式主动脉瓣中交界方向ICC=0.98(95%CI:0.96-0.99),融合瓣几何高度ICC=0.91(95%CI:0.74-0.97)。

临床怎么用

  • 对于拟行主动脉瓣修复的年轻患者,可在超声心动图基础上加做心电图门控心脏CT以辅助评估瓣膜形态和交界方向。
  • 在二叶式主动脉瓣中可参考CT测量的融合瓣几何高度,在三叶式主动脉瓣中可参考CT测量的瓣环直径和左冠瓣几何高度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: In young patients with type I/II aortic regurgitation, the feasibility of aortic valve (AV) repair has been traditionally evaluated with echocardiography. We evaluate electrocardiogram (ECG)-gated cardiac computed tomography as a complement to transoesophageal echocardiography in the preoperative assessment of aortic repairability. METHODS: Patients undergoing non-urgent AV repair with or without aortic root replacement from October 2016 to May 2023 who had both imaging tests for the evaluation of AV repairability were included. The measurements obtained with echocardiography and ECG-gated scan of geometric height, aortic annulus and commissural orientation were compared using the intraclass correlation coefficient for inter-rater reliability. RESULTS: All 24 patients were males, with a median age of 47.5 years (41.9-59.3). Of these, 87.5% presented severe aortic regurgitation; 62.5% had associated aortopathy. 58.3% were in New York Heart Association class I and the remnant 41.7% in class II. The AV was bicuspid in 62.5% of the patients. The intraclass correlation coefficient indicated excellent reliability of ECG-gated scan for commissural orientation (ICC = 0.98, 95% CI: 0.96-0.99) and conjoined cusp geometric height (ICC = 0.91, 95% CI: 0.74-0.97) in bicuspid AVs, while in tricuspid valves it showed good reliability for left cusp geometric height (ICC = 0.76, 95% CI: 0.19-0.93) and annular diameter (ICC = 0.8, 95% CI: 0.33-0.95). CONCLUSIONS: ECG-gated cardiac scan complements echocardiography in aortic repair, showing excellent agreement for morphologic evaluation and commissural orientation. It is particularly reliable for geometric height in bicuspid valves and annular diameter and left cusp geometric height in tricuspid valves.

来源:Interdiscip Cardiovasc Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Mescola V, Álvarez Asiaín V, De Diego Candela J, et al. Use of complementary electrocardiogram-gated cardiac computed tomography in the assessment of aortic valve repairability: a pilot study†. Interdiscip Cardiovasc Thorac Surg. 2025. PMID: 40234245. doi:10.1093/icvts/ivaf086

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。