离体猪主动脉模型四维血流磁共振评估主动脉瓣置换术前后的主动脉血流
本研究建立离体猪主动脉搏动泵模型,用四维血流磁共振比较主动脉瓣置换术前、 sham手术及三种瓣膜置换术后的血流模式。结果显示sham手术即可诱导二次血流,生物瓣后二次血流最明显,且峰值流速在三种置换术后均升高,以生物瓣为著。
要点
- sham手术(主动脉切开缝合)即可在升主动脉诱导二次血流模式。
- 生物瓣置换后二次血流模式数量最多,其次为Ozaki手术和机械瓣。
- 所有主动脉瓣置换术后主动脉窦内峰值流速均升高,生物瓣最显著。
核心结论
- 离体猪主动脉模型成功建立,提示血流改变不仅取决于主动脉瓣置换类型,也与手术入路相关。
- 生物瓣置换后二次血流模式最强,其次为Ozaki手术和机械瓣。
研究设计与样本
- 离体猪主动脉(n=6)吻合至定制活塞泵,以模拟血液流体在2.5 l/min和64 bpm下灌注。
- 每根主动脉在术前(NAV,n=6)、sham手术后(NAV-A,n=6)及Ozaki手术(AVneo,n=2)、生物瓣(BV,n=2)或机械瓣(MV,n=2)后行四维血流磁共振成像。
主要发现
- sham手术 alone 在所有标本的升主动脉诱导二次血流模式。
- 主动脉瓣置换后,生物瓣远端观察到的二次血流模式多于AVneo或MV;生物瓣后出现三种血流模式,AVneo后两种,MV后一种。
- 主动脉窦内峰值流速在所有主动脉瓣置换术后均升高,以生物瓣最显著(NAV=75±22 cm/s,NAV-A=79±29 cm/s,AVneo=115±36 cm/s,BV=142±21 cm/s,MV=107±4 cm/s;mean±standard deviation)。
临床怎么用
- 该离体模型可用于标准化分析手术入路和不同主动脉瓣置换技术对升主动脉血流的影响。
- 临床选择瓣膜类型时需考虑术后二次血流模式及峰值流速变化,生物瓣后二次血流更明显。
局限性
- 样本量小(每组主动脉瓣置换仅n=2),结果需进一步验证。
- 离体猪模型不能完全代表在体生理条件。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Aortic valve replacement (AVR) has shown to induce secondary flow patterns deviating from main flow. It is impossible to analyse the impact of surgical access and different AVR techniques under standardized conditions in patients or silicone models. Therefore, we developed an ex vivo swine model to analyse the impact of surgical access and to compare flow patterns after different AVR techniques within the ascending aorta. METHODS: Porcine aortas (n = 6) were anastomosed to a custom-made piston pump. The pulse duplicator perfused the aortas with a blood-mimicking fluid at 2.5 l/min and 64 bpm. 4D flow magnetic resonance imaging of each aorta was acquired prior to surgery (NAV, n = 6), after sham surgery (aortotomy and closure thereof without valve replacement, NAV-A, n = 6) and after Ozaki procedure (AVneo, n = 2), biological valve (BV, n = 2) or mechanical valve (MV, n = 2). Secondary flow patterns and peak velocity were analysed with GTFlow (GyroTools, Switzerland). RESULTS: Sham surgery alone induced secondary flow patterns in the ascending aorta in all specimens. After AVR, more secondary flow patterns were observed distal to BV compared to AVneo or MV. Three flow patterns developed after BV, two after AVneo and one after MV. In addition, peak velocity within the aortic sinuses of Valsalva increased after all AVR procedures, most strikingly after BV (NAV = 75 ± 22 cm/s, NAV-A = 79 ± 29 cm/s, AVneo = 115 ± 36 cm/s, BV = 142 ± 21 cm/s, MV = 107 ± 4 cm/s; mean±standard deviation). CONCLUSIONS: We successfully established an ex vivo model suggesting that flow alterations not only depend on the type of AVR but are associated with surgical access. The strongest secondary flow patterns developed after BV followed by AVneo and MV.