人工智能三维模拟基于平扫CT评估肺血管与体积的准确性
本研究纳入18例接受解剖性肺切除术的肺癌患者,利用人工智能软件分别基于增强CT(ECT)和平扫CT(UECT)自动构建支气管血管树三维图像。结果显示UECT识别动脉分支(PAs)96.6%、静脉分支(PVs)82.1%,与ECT的98.9%和85.7%接近;UECT未检出ECT所识别的16支PAs(4.4%)和32支PVs(10.1%),分支检测相关系数0.9783(P<0.001)。结论认为UECT数据的三维图像在肺叶及部分肺段分支水平可能与ECT相当。
要点
- UECT识别PAs 96.6%、PVs 82.1%,与ECT的98.9%和85.7%接近。
- UECT未检出ECT所识别的4.4% PAs和10.1% PVs。
- UECT与ECT测量的动脉导向体积在右侧(R=0.8330)和左侧(R=0.8082)均显著相关。
核心结论
- 基于UECT数据的三维图像技术在肺叶及部分肺段分支水平可能与ECT数据相当。
研究设计与样本
- 单中心研究纳入18例接受解剖性肺切除术的肺癌患者。
- 使用Synapse Vincent系统(Fujifilm Corporation,东京,日本)的人工智能软件Version6.7,分别基于ECT和UECT自动构建支气管血管树三维图像。
- 评估UECT识别肺血管的准确性,并比较UECT与ECT计算的肺段体积。
主要发现
- 与手术所见比较,ECT识别98.9%的动脉分支(PAs)和85.7%的静脉分支(PVs),UECT识别96.6%的PAs和82.1%的PVs。
- ECT识别的371支PAs和319支PVs中,UECT未检出16支PAs(4.4%)和32支PVs(10.1%),分支检测相关系数0.9783(P < 0.001)。
- ECT与UECT测量的动脉导向体积在右侧肺段(R = 0.8330)和左侧肺段(R = 0.8082)均显著相关。
临床怎么用
- 对于无法接受增强CT的患者,可考虑使用基于UECT的人工智能三维模拟辅助解剖性肺切除术的术前规划。
- 需注意UECT对静脉分支的识别率略低(82.1%),术前应结合手术所见审慎评估。
局限性
- 样本量较小(18例),可能影响结果的普遍性。
- 原文未报告其他局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The advantages of preoperative three-dimensional (3D) image simulations, which require enhanced computed tomography (ECT), for anatomical lung resection are well documented. However, the necessity for contrast agent presents a significant barrier for some patients. This study thus aims to evaluate the accuracy of an artificial intelligence-based 3D simulation using unenhanced computed tomography (UECT) data in comparison to ECT data. METHODS: The study enrolled 18 lung cancer patients who underwent anatomical lung resections. Utilizing the artificial intelligence software Version6.7 within the Synapse Vincent system (Fujifilm Corporation, Tokyo, Japan), automatic construction of 3D images of the bronchovascular trees was achieved using both ECT and UECT. We further assessed the accuracy of pulmonary vessel identification on UECT, and compared the calculated lung segment volumes obtained from UECT with those obtained from ECT. RESULTS: The comparison of accuracy to operative findings showed that ECT identified 98.9% of artery branches (PAs) and 85.7% of vein branches (PVs), while UECT identified 96.6% of PAs and 82.1% of PVs. Out of 371 PAs and 319 PVs identified on ECT, UECT failed to detect 16 PAs (4.4%) and 32 PVs (10.1%), yielding a correlation coefficient for branch detection of 0.9783 (P < 0.001). There was a significant correlation between ECT and UECT in measuring artery-oriented volumes on both the right-side segments (R = 0.8330) and the left-side segments (R = 0.8082). CONCLUSIONS: This 3D image technique using UECT data may be comparable to that obtained with ECT data in terms of achieving lobar and partial segmental branch levels.
引用
- Fukuta K, Shimada Y, Nagamatu Y, et al. Accuracy of artificial intelligence-based simulation for assessing lung vessels and volume using unenhanced computed tomography. Eur J Cardiothorac Surg. 2025. PMID: 40120091. doi:10.1093/ejcts/ezae449
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。