A型主动脉夹层修复术后血压与心率管理
本研究基于长庚研究数据库2003至2018年839例急性A型主动脉夹层术后存活出院患者,评估出院时及随访3个月血压与心率对长期结局的关联。结果显示出院时收缩压>150 mm Hg与全因死亡率升高相关,心率>80次/分与全因死亡及主动脉手术事件风险增加相关。
要点
- 出院时收缩压>150 mm Hg与全因死亡率升高独立相关。
- 出院时心率81-100次/分及>100次/分分别与全因死亡和主动脉手术事件风险增加相关。
- 随访3个月心率>100次/分与全因死亡率升高相关。
核心结论
- A型主动脉夹层术后精细管理血压和心率有助于改善长期结局。
研究设计与样本
- 回顾性队列研究,纳入长庚研究数据库2003至2018年839例急性A型主动脉夹层术后存活出院患者。
主要发现
- 出院时收缩压>150 mm Hg与全因死亡率升高相关(aHR 3.21;95% CI 1.61-6.37)。
- 出院时心率81-100次/分与全因死亡率升高相关(aHR 2.59;95% CI 1.28-5.24)。
- 出院时心率>100次/分与主动脉手术事件风险升高相关(aHR 2.19;95% CI 1.24-3.86)。
- 随访3个月心率>100次/分与全因死亡率升高相关(aHR 3.59;95% CI 1.19-10.78)。
临床怎么用
- 术后应关注出院时收缩压,避免超过150 mm Hg。
- 术后应控制心率,出院时及随访中尽量维持≤80次/分。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The long-term optimal targets for blood pressure and heart rate in patients after surgical repair of acute type A aortic dissection (TAAD) remain unclear. This study evaluated the long-term association of blood pressure and heart rate control on patients after TAAD surgical repair. METHODS: We identified 839 patients who underwent TAAD surgical repair and survived to discharge between 2003 and 2018 from the Chang Gung Research Database. Primary outcomes included all-cause mortality, aortic progression, and aortic surgery events. Vital signs examined were systolic blood pressure (SBP), diastolic blood pressure, and heart rate (HR) at discharge and at 3 months of follow-up. RESULTS: The patients were a mean age of 57.2 ± 13.6 years, and approximately two-thirds were men. The results showed that SBP >150 mm Hg at discharge was correlated with increased all-cause mortality (adjusted hazard ratio [aHR], 3.21; 95% CI, 1.61-6.37). Moreover, an HR between 81 and 100 beats/min was associated with a higher hazard of all-cause mortality (aHR, 2.59; 95% CI, 1.28-5.24) and an HR >100 beats/min was also associated with a higher hazard of aortic surgery events (aHR, 2.19; 95% CI 1.24-3.86) compared with an HR of ≤80 beats/min at discharge. During the 3-month follow-up, an HR >100 beats/min was associated with a higher hazard of all-cause mortality (aHR, 3.59; 95% CI, 1.19-10.78) relative to an HR ≤80. CONCLUSIONS: The careful management of blood pressure and HR contributes to favorable long-term outcomes in patients after surgical repair of TAAD.
引用
- Ho CH, Lin CP, Chang FC, et al. Blood Pressure and Heart Rate Management in Patients After Repair of Type A Aortic Dissection. Ann Thorac Surg. 2025. PMID: 40057152. doi:10.1016/j.athoracsur.2025.02.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。