保留瓣膜的主动脉根部置换术治疗瓣旁开窗:哪些瓣膜会失败?
该多中心前瞻性队列研究基于德国主动脉根部修复注册(GEARR)数据,筛选出145例存在瓣旁开窗的保留瓣膜主动脉根部置换术(VSARR)患者。主要终点为体外循环后经食道超声残余主动脉瓣反流(rAR)、中期rAR进展及因AR行主动脉瓣置换。3年无终点事件率为78%(99% CI 74-79%),多瓣叶开窗、游离缘长度差≥5mm及瓣叶脱垂与更差结局相关。
要点
- 多瓣叶开窗、游离缘长度差≥5mm及合并脱垂提示VSARR后结局较差。
- 游离缘长度差<5mm者3年无终点事件率86%,显著优于≥5mm者的41%。
- 瓣叶脱垂且游离缘长度差>5mm者结局最差,3年无终点事件率仅30%。
核心结论
- 瓣旁开窗患者行VSARR后,多瓣叶开窗、游离缘长度不均及合并脱垂与更差结局相关。
研究设计与样本
- 多中心前瞻性意向治疗VSARR注册研究(德国主动脉根部修复注册GEARR),2016-2024年共762例患者,筛选出145例存在至少一个瓣旁开窗者。
主要发现
- 18例(12%)未按计划行VSARR而改行带瓣管道(CVG)植入。
- 体外循环后经食道超声显示rAR 1级或2级者44例(33%),3级者3例(2%)。
- 多瓣叶开窗患者中50%出现rAR早期进展。
- 3年无复合终点事件率全队列为78%(99% CI 74-79%)。
- 游离缘长度差<5mm者3年无终点事件率86%(99% CI 80-91%),≥5mm者为41%(99% CI 38-46%,P=0.011)。
临床怎么用
- 对瓣旁开窗患者行VSARR前应评估开窗累及瓣叶数量、游离缘长度差及是否合并脱垂,以预判失败风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To define morphologic risk constellations during valve-sparing aortic root replacement (VSARR) for aortic valves with paracommissural fenestrations. METHODS: Patients from the multicentre prospective intention-to-treat VSARR-registry German Aortic Root Repair Registry (GEARR) were screened for paracommissural cusp fenestrations. We studied a combined end-point of residual aortic regurgitation (rAR) on post-cardiopulmonary bypass (CPB) transesophageal echocardiography (TEE), mid-term progress of rAR (transthoracic echocardiography) and aortic valve replacement for AR. RESULTS: Of a total of 762 registry patients (operated 2016-2024), 145 were identified with ≥1 paracommissural cusp fenestration. Eighteen patients (12%) were not treated as planned but underwent composite valved graft (CVG) implantation. Mean follow-up time was 3 years. Upon post-CPB TEE, rAR grade 1 or 2 were present in 44 (33%) and 3 (2%) patients. 50% of patients with fenestrations in more than one cusp showed early progression of rAR. At 3 years, freedom from the combined end-point was 78% (99% CI 74-79%) for the complete study cohort. Patients with a maximum free margin length difference of <5 mm, reflecting balanced root anatomy with respect to sinus and cusp sizes, had a significantly better outcome than those with ≥5 mm: at 3 years, freedom from the combined end-point was 86% (99% CI 80-91%) vs 41% (99% CI 38-46%, P = 0.011). Outcome was worst for patients with cusp prolapse and a free margin length difference of >5 mm (30% vs 70%, P = 0.018). CONCLUSIONS: Fenestrations in more than one cusp, inhomogeneities of cusp-free margin lengths, and additional prolapse are associated with inferior outcome after VSARR for valves with paracommissural fenestrations. CLINICAL TRIAL REGISTRATION NUMBER: DRKS00007872.
引用
- Kari FA, Czerny M, Borger M, et al. Valve-sparing aortic root replacement for valves with paracommissural fenestrations: which valve will fail? Eur J Cardiothorac Surg. 2025. PMID: 39891405. doi:10.1093/ejcts/ezaf034