文献速递冠心病外科

计算流体力学模拟冠状动脉端侧吻合狭窄病变的血流动力学影响

Computational fluid dynamics to simulate stenotic lesions in coronary end-to-side anastomosis.
PubMed 文献 · Interdiscip Cardiovasc Thorac Surg · 2025-01-01

本研究通过猪心左前降支端侧吻合模型,利用多层螺旋CT获取图像并构建25%至100%不同狭窄程度的计算流体力学模型,分析流线、壁面剪切应力和振荡剪切指数。结果显示75%纵向或双侧狭窄导致异常血流分离、低壁面剪切应力和高振荡区域,提示内膜增生风险,而狭窄<50%时血流动力学可接受。

要点

  • 端侧吻合口75%纵向或双侧狭窄时,吻合口远端出现异常血流分离和低壁面剪切应力,预测内膜增生风险。
  • 吻合口狭窄<50%时血流动力学可接受,提示临床可接受该程度狭窄。
  • 计算流体力学可模拟端侧吻合狭窄的血流动力学效应,辅助评估手术吻合质量。

核心结论

  • 计算流体力学模型预测端侧吻合口75%纵向或双侧狭窄有内膜增生导致移植失败的风险,而狭窄<50%时血流动力学可接受。

研究设计与样本

  • 离体猪心模型:颈动脉经端侧吻合移植至左前降支,注入液态硅胶后行多层螺旋CT获取参考图像,构建25%、50%、75%、90%和100%纵向缩短及双侧狭窄模型,进行计算流体力学模拟分析流线、壁面剪切应力和振荡剪切指数。

主要发现

  • 参考模型中移植血管流入冲击自体动脉底部,在足跟附近产生再循环涡流和高振荡剪切指数区域。
  • 随着纵向狭窄增加,移植血管流入角度增大;双侧狭窄在自体动脉侧壁附近产生螺旋流,并随狭窄程度加重而恶化。
  • 75%狭窄时,纵向缩短和双侧狭窄均导致异常血流分离,吻合口远端出现低壁面剪切应力和高振荡区域。

关键数值与推荐

  • 端侧吻合口纵向或双侧狭窄75%时,出现异常血流分离、低壁面剪切应力和高振荡区域,预测内膜增生风险。
  • 端侧吻合口狭窄<50%时,血流动力学可接受。

临床怎么用

  • 心胸外科医生在构建端侧吻合时应避免纵向或双侧狭窄达到75%,以降低内膜增生和移植失败风险;狭窄<50%时血流动力学可接受。

局限性

  • 本研究为离体计算流体力学模拟,非在体临床研究,未来需探索次优手术吻合构建的长期临床结局。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: End-to-side anastomosis is common in coronary artery bypass grafting, although restrictive suturing can narrow the anastomosis. We evaluated ex vivo end-to-side models by numerically simulating fluid dynamics to compare various degrees of stenotic anastomoses to predict haemodynamic effects. METHODS: A carotid artery was grafted via an end-to-side anastomosis onto the left anterior descending artery of a porcine heart, with liquid silicone injected into the vessels. The end-to-side image was acquired via multidetector computed tomography for reference, and models of longitudinal shortening and bilateral narrowing were created with 25%, 50%, 75%, along with 90%, and 100% stenosis in the native coronary artery. Haemodynamics were analysed using computational fluid dynamics simulations to calculate streamlines, wall shear stress and oscillatory shear index. RESULTS: In the reference model, the graft inflow impinged on the floor of the native artery, creating a recirculating vortex and a high oscillatory shear index region near the heel. As the graft flow angle increased with longitudinal stenosis, bilateral stenosis generated helical flow near the lateral wall of the native artery, worsening with increased stenosis. At 75% stenosis, both longitudinal shortening and bilateral narrowing caused abnormal flow separation, with low wall shear stress and high oscillatory regions forming distal to the toe of the anastomosis. CONCLUSIONS: Computational fluid dynamics modelling predicts that end-to-side anastomoses with 75% longitudinal or bilateral stenosis are at a risk of intimal hyperplasia causing graft failure, while anastomotic stenosis <50% indicates acceptable haemodynamics. Future studies should explore long-term clinical outcomes with suboptimal surgical anastomotic construction. CLINICAL REGISTRATION NUMBER: Not applicable.

来源:Interdiscip Cardiovasc Thorac Surg,查看原文。版权归原作者所有。

引用

  1. Kamiya K, Terada S, Nagatani Y, et al. Computational fluid dynamics to simulate stenotic lesions in coronary end-to-side anastomosis. Interdiscip Cardiovasc Thorac Surg. 2025. PMID: 39886947. doi:10.1093/icvts/ivaf013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。