单中心回顾334例心脏移植,按预测心质量比分为偏小组(<0.86)、匹配组(0.86-1.15)和偏大组(>1.15)。偏小组30天和1年生存显著更差,但亚组分析显示差异仅见于复杂移植组;非复杂移植组中偏小供心血流动力学和生存与匹配或偏大组相似。

要点

  • 偏小PHM比(<0.86)供心与1年死亡率增加相关。
  • 生存差异仅见于复杂移植组(LVAD、成人先心或ECMO)。
  • 非复杂移植中偏小供心血流动力学和生存与匹配或偏大组相似。

核心结论

  • 偏小PHM比供心与1年死亡率增加相关,由复杂移植手术驱动。
  • 非复杂移植中接受偏小PHM比供心的受者血流动力学和生存与匹配或偏大组相似。
  • 偏小PHM比供心可能可选择性地安全用于移植。

研究设计与样本

  • 单中心分析2019年1月至2022年7月334例孤立心脏移植受者。
  • 按PHM比分层:偏小<0.86(n=106)、匹配0.86-1.15(n=175)、偏大>1.15(n=53)。

主要发现

  • 偏小患者更可能有持久性左心室辅助装置(P = .022)。
  • 术后原发性移植物功能障碍和正性肌力药评分组间相似。
  • 偏小供心术后透析需求有增加趋势(P = .056)。
  • 偏小组30天生存(P = .012)和1年生存(P = .002)显著更差。
  • 亚组分析显示生存差异仅见于复杂移植受者(P = .013),非复杂移植受者无差异(P = .428)。

关键数值与推荐

  • PHM比分层阈值:偏小<0.86,匹配0.86-1.15,偏大>1.15。
  • 所有心脏大小组中位混合静脉血氧饱和度维持在65%至70%,心脏指数在2.4至2.8 L/min/m2。

临床怎么用

  • 复杂移植(术前LVAD、成人先心或ECMO)应避免使用偏小PHM比供心。
  • 非复杂移植中偏小PHM比供心可能可安全使用,但需个体化评估。

局限性

  • 单中心回顾性分析,样本量有限。
  • 复杂移植亚组样本量小,结果需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Predicted heart mass (PHM) ratio has become the standard donor-recipient size matching method in heart transplantation. Although use of small PHM ratio hearts is associated with increased 1-year mortality, the underlying mechanisms and time horizon of mortality remain uncertain. METHODS: A single-institution analysis of 334 isolated heart transplant recipients (January 2019-July 2022) was performed. Patients were stratified by PHM ratio: undersized (<0.86; n = 106), matched (0.86-1.15; n = 175), and oversized (>1.15; n = 53). Survival within PHM ratio groups was further stratified by complex transplant group (preoperative left ventricular assist device, adult congenital, or preoperative extracorporeal membrane oxygenation) and noncomplex transplant group (all others). RESULTS: Donor and recipient variables were similar. However, undersized patients were more likely to have a durable left ventricular assist device (P = .022). Although postoperative primary graft dysfunction and inotrope score were similar between groups, there was a trend toward increased need for postoperative dialysis with undersized hearts (P = .056). Overall, 30-day (P = .012) and 1-year survival (P = .002) was significantly worse in the undersized group compared with the matched or oversized groups. However, subset analysis showed these differences only remained among the complex transplant recipients (P = .013) but not the noncomplex transplant recipients (P = .428). Median mixed venous oxygen saturations at serial time points were maintained between 65% and 70% in all heart size groups, with cardiac indices between 2.4 and 2.8 L/min/m2. CONCLUSIONS: Small PHM ratio hearts are associated with increased 1-year mortality, driven by complex transplant operations. Recipients who received undersized PHM ratio hearts from noncomplex transplant operations had a similar hemodynamic profile and survival as those who received matched and oversized hearts. Small PHM ratio hearts may be selectively safe for transplantation.