离体肺亚肺叶切除模型中CT评估手术切缘的可行性
本研究利用含琼脂糖假肿瘤的猪肺楔形样本建立离体亚肺叶切除模型,比较CT、大体固定前、固定后及病理四个阶段的手术切缘长度。共分析50个样本,CT测量切缘平均14.0 mm,病理平均10.9 mm,从CT到最终病理平均变化-23.8%(P < 0.001),提示CT测量通常高估病理切缘。
要点
- CT测量手术切缘在离体模型中可行,但与最终病理平均不一致达23.8%。
- CT测量切缘通常高估病理切缘,94%样本处理后切缘缩短。
- 外科医生需知晓CT评估切缘可能高估实际病理切缘。
核心结论
- 基于CT的手术切缘测量在离体亚肺叶切除模型中可行,但与最终病理测量平均不一致为23.8%。
- CT衍生的手术切缘通常高估病理衍生的手术切缘。
研究设计与样本
- 离体实验研究,使用含琼脂糖假肿瘤的猪肺楔形样本,共分析50个肺标本。
- 获取标本 Inflation 后CT图像,沿CT观察平面切开标本,固定后制作H&E切片,比较四个阶段的手术切缘长度。
主要发现
- 标本处理后手术切缘长度缩短占94%(47/50),增加占6%(3/50)。
- 平均手术切缘长度:CT 14.0 mm(范围4.5-28.3 mm),大体固定前13.0 mm(范围4.0-25.0 mm),大体固定后12.1 mm(范围2.5-26.0 mm),病理10.9 mm(范围1.0-23.4 mm)。
- 从CT到最终病理的手术切缘长度平均变化-23.8%(范围+11%至-82%),P < 0.001。
临床怎么用
- 心胸外科医生应意识到CT评估的手术切缘可能高估最终病理切缘,术中决策需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Computed tomography (CT) imaging of a sublobar resection specimen may inform intraoperative surgical margin assessment. However, consistency with final pathological margins has not been previously evaluated. In this study, we investigated the concordance between surgical margin measurements by CT versus pathology measurements using an ex vivo sublobar lung resection model. METHODS: Pig lung wedge samples containing agarose pseudotumours were harvested. CT images were acquired following specimen inflation. The specimen was bisected along the same plane observed by CT for accurate comparison with pathological surgical margin measurement. The bisected samples were then fixed in formalin before preparing haematoxylin & eosin slides. Surgical margin length at four distinct stages (CT, gross pre-formalin fixation, gross post-formalin fixation and pathology) were measured and compared. RESULTS: A total of 50 lung specimens were analysed. After specimen processing, Surgical margin length decreased in 94% (47/50) and increased in 6% (3/50) of samples. Mean surgical margin lengths were as follows: CT 14.0 mm (range: 4.5-28.3 mm), gross pre-formalin fixation 13.0 mm (range: 4.0-25.0 mm), gross post-formalin fixation 12.1 mm (range: 2.5-26.0 mm) and pathology 10.9 mm (range: 1.0-23.4 mm). There was an average -23.8% (range: +11 to -82%) change in surgical margin length from CT to final pathology (P < 0.001). CONCLUSIONS: While CT-based surgical margin measurement is feasible, we observed an average 23.8% discordance when compared to final pathology measurement. Surgeons must be aware that the CT-derived surgical margin generally overestimates the pathology-derived surgical margin.
引用
- Kitazawa S, Bernards N, Gregor A, et al. Feasibility of computed tomography-derived surgical margin assessment in an ex vivo sublobar lung resection model. Interdiscip Cardiovasc Thorac Surg. 2024. PMID: 39673785. doi:10.1093/icvts/ivae211
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。